background image

33

ENGLISH

 CHAP.09 FAULT DIAGNOSIS AND TROUBLESHOOTING

 09.1  PROBLEMS

 In accordance with the laws in force on safety for electrical appliances, a specialised Technical Service Center 

or qualified personnel must obligatorily be contacted for all installation, maintenance or interventions that require access to 

electrical parts.

WARNING

PROBLEM

MAIN CHECKS TO BE PERFORMED

The Emergency Display is 
not on

• 

Check that the stove plug is inserted securely in the mains socket and the socket at the back of the stove.

• 

Check that the FLAT cable is connected to the electronic circuit board correctly.

•  Check that the protection fuses are working efficiently, including those connected to the electronic circuit 

board and those in the stove rear socket.

The radio remote control 
does not work

• 

Check that the batteries are the ALKALINE type and not 1.5 V AA rechargeable batteries, and they are 

inserted correctly. Do not use rechargeable batteries.

• 

Point the radio remote control at the display on the edge of the stove.

• 

Check that the stove is powered up and the display is working.

The pellets are not 
dropping into the
firebox

•  The pellets have run out, refill the container.

• 

The gear motor is not running, check the reason:

- not connected to the mains
- mechanically disconnected from the auger.

• 

The auger is blocked by a foreign body which has fallen into the container.

• 

The auger is blocked by very hard pellets; use the recommended pellet types.

• 

The auger is blocked by a safety device triggered by the manual reset thermostat or the fumes safety pressure 

switch.

The stove does not start 
automatically

•  The firebox is dirty, preventing incoming air flow. Clean it thoroughly and check it is clean each time you 

start it up.

• 

The basket is positioned incorrectly.

• 

The resistance is faulty

T h e   p e l l e t s   b u r n 
incorrectly and unburnt
elements gather in the 
basket, the glass looks 
black and is very dirty

•  Low flue draught, do not use the fireplace, it could be dangerous; carefully clean the flue, the stove and the 

fume extractor.

•  Firebox is very dirty. Switch off the stove and clean it.

• 

Humid pellets. Replace the fuel.

•  Lack of comburent air, check that the front door is firmly shut against the stove structure.

• 

Incorrect fan settings; check the default and factory settings.

The stove switches off 
when running at minimum 
power.

• 

The combustion fan speed is very high and the pellets are burning too quickly.

• 

The pellet supply is running out.

•  The flue draught rate is high.

• 

The amount of loaded pellet is high, it does not all burn within the set time and fresh pellets accumulate inside 

the firebox. Adjust the load level, or increase the combustion fan speed.

The flame is very 
inconsistent

• 

Check the bottom of the pellet container; there may be large deposits of sawdust.

• 

The gear motor may have broken gearings.

The exchange and/
or combustion fan are 
running when the stove is
switched off

•  The flue probe is broken. Replace it

The electric components 
are running when the 
stove is switched off

• 

The electronic circuit board is broken. Replace it.

The exchange fan air 
smells of smoke

• 

Check the exchange fan, it might be dirty.

The exchange fan whistles 
or is very noisy

• 

Check the exchange fan, it might be dirty.

For a detailed list of alarm messages, see the enclosed manual SM095.

NOTE

Содержание AMBRIA2

Страница 1: ...SM122 EN REV06 2021_06 AMBRIA2 6 kW AMBRIA2 8 kW INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Pellet operated air heating stove AMBRIA2...

Страница 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Страница 3: ...CHAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDED FUELS 15 06 3 COMPONENTS 16 06 4 DIMENSIONS 17 CHAP 0...

Страница 4: ...more restrictive in this instance comply fully with the regulations prevailing in the country of installation all laws and local bylaws must be observed when installing and using the appliance includ...

Страница 5: ...old electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations for appliances fitted with g...

Страница 6: ...right to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER LIABILITY AND WARRANTY CONDITIONS Upon the delivery...

Страница 7: ...ensory or mental capabilities or lacking the experience or the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and on the understanding of...

Страница 8: ...ce with the laws and standards in force in the State Region or Area in which the machine is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly...

Страница 9: ...urs of operation shall be reset at the end of the Technical intervention and indicated on the Servicing Report 02 4 EQUIPMENT FOR OPERATORS AND MAINTENANCE PERSONNEL Every operator performing maintena...

Страница 10: ...03 2 LIFTING AND TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY REGULATIONS of this manu...

Страница 11: ...rective 2012 19 UE waste electrical and electronic equipment WEEE information for users The crossed out wastebasket symbol on the appliance means that at the end of its useful lifespan the product mus...

Страница 12: ...l with Display Wide backlit LCD display allowing operators to interface with the product set the operating parameters and receive work status data Timer controlled thermostat used to set the start up...

Страница 13: ...O Tensione Frequenza nominale Rated voltage frequency Spannung Nennfrequenz Tension Fr quence nominale Tensi n Frecuencia nominal Temperatura dei fumi Flue gas temperature Abgastemperatur Temp rature...

Страница 14: ...Switching on nominal power reduced power stand by 310 60 15 2 2 310 65 15 2 2 W Device mass 110 110 Kg Standard hopper capacity 15 15 Kg Flue draught Nominal heat output Reduced heat output 10 0 8 0...

Страница 15: ...use pellets that are very hard and with different dimensions the mechanical parts are sized and tested for use with pellets with the above mentioned characteristics No breakdown or malfunction depend...

Страница 16: ...r loading pellets 4 Emergency console 5 Firebox 6 Ash drawer 7 Combustion chamber door 8 Pellet hopper 9 Electronic control unit 10 Fume pressure switchi 11 Comburent air inlet tube 50 mm 12 Room temp...

Страница 17: ...17 ENGLISH 06 4 DIMENSIONS All measurements are in mm AMBRIA2 6 kW AMBRIA2 8 kW A 461 5 B 1073 C 487 8 AMBRIA2 6 kW AMBRIA2 8 kW C A B...

Страница 18: ...exhaust pipes and flue can be easily accessed for maintenance Fig 1 illustrates minimum distances that must be observed all measures must be in mm The lateral distance from the adjacent wall according...

Страница 19: ...re are deviations or curves for easier quicker and safer installation we recommend using double walled stainless steel pipes The use of pipes in fibre cement for connecting the equipment to the flue i...

Страница 20: ...hand the purchaser MUST assign all work to a qualified professional technician The device must be installed and used in accordance with all local and national laws and EC Regulations WARNING In the e...

Страница 21: ...opening needs to be designed in compliance with the specifications in paragraph 07 3 4 All models may be connected to the fume pipes with rear fume outlet Fig 1 For the construction of fume pipes plea...

Страница 22: ...force 2014 30 UE and 2014 35 UE WARNING Number Description 1 Radio control 2 Electronic card 3 Bipolar switch 4 Electric power cord with schuko socket 5 Smoke fan 6 Electrical heating element 7 Excha...

Страница 23: ...ontrol unit connected by radio frequency to the radio remote control manages all the device functions and the LCD display screen on the handheld console can be used to monitor all the stove operating...

Страница 24: ...ET ambient temperature which correspond to the automatic start up value of the stove In this condition the stove is not actually off but is waiting to turn back on if the above conditions are satisfie...

Страница 25: ...Wait until the appliance is completely cold on average 20 minutes 2 Unscrew the thermostat reset button lid on the back of the appliance see Fig 1 positions B 3 Press the button until you hear a CLIC...

Страница 26: ...hopper using a scoop Do not empty the sack directly into the hopper Check for obstructions in the flue and in the external air intake before starting the machine after a prolonged period of disuse Th...

Страница 27: ...use an ash vacuum not supplied with the stove but available from retailers and or specialised Technical Service Centers ORDINARY CLEANING THE INSTRUCTIONS BELOW REGARDING THE TIMING AND METHODS USED...

Страница 28: ...rnal walls and shaking it eventually Before replacing the firebox check there is no ash or dirt in the firebox housing Vacuum this area thoroughly too make sure residual ashes are cold Fig 8 Make sure...

Страница 29: ...Never spray detergents directly on cladding parts Fig 22 Use of abrasive and or corrosive chemical products can damage the painted parts and are reason for invalidation of the warranty on these parts...

Страница 30: ...into the domestic electrical system turn the switch to I see Fig 28 10 Pellet hopper loading Located on the rear part of the device the hopper is filled through an openable lid The hopper must be fill...

Страница 31: ...th special focus on horizontal segments Stove fume pass cleaning Cleaning of any deposits in the stove Cleaning of fans Check good ignition resistance operations Check electric electronic system integ...

Страница 32: ...at and pressure switch status and efficiency T Check the condition of the sealing gaskets paying special attention to the one on the closure of the combustion chamber door T Check the condition of the...

Страница 33: ...s safety pressure switch The stove does not start automatically The firebox is dirty preventing incoming air flow Clean it thoroughly and check it is clean each time you start it up The basket is posi...

Страница 34: ...34 NOTES...

Страница 35: ...35 ENGLISH NOTES...

Страница 36: ...SM122 EN REV06 2021_06 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...

Отзывы: