background image

13

ENGLISH

The illustrated example plate may differ in graphics from the original affixed to the product.

NOTE

Product model

CE marking

Year of commissioning and certification

4

 

Reference standard

Performance declaration No.*

6

 

Product LOT N°

Product code

Product serial number

 

05.2 

PRODUCT IDENTIFICATION

It is COMPULSORY to indicate the product MODEL, the LOT number 

and SERIAL NUMBER in all communications with the Manufacturer.

Identification numbers are printed on the adhesive plate located on 

the back of the device as illustrated on the right. Stove performance 

values measured during inspection tests according to the indicated 

reference and EC markings are also included on the plate.

*Pursuant to European Regulation No. 305/2011, manufacturers are now required to have the DoP - Declaration of 

Performance for each product of own design concerned; Jolly-Mec did namely provide all of these documents in downloadable electronic 

form that you can easily see on the website of the Company at the following address: http://www.jolly-mec.it.

WARNING

Via San Giuseppe, 2 - 24060 Telgate - BG - ITALY

Tel. +39.035.8359211 - fax +39.035.8359200

www.jolly-mec.it - [email protected]

Potenza elettrica nominale

Rated electrical power

Elektr. Leistungsaufnahme

Puissance électrique nominale

Potencia eléctrica nominal

Distanza minima materiali combustibili adiacenti

Min. clearance from combustible materials

Abstand zu angrenzenden entzündlichen Stoffen

Distance aux matériaux combustibles

Distancia a materiales combustibles adyacentes

Utilizzare solo combustibili raccomandati

Use recommended fuels only

Verwenden Sie nur die empfohlenen Brennstoffsorten

Utiliser seulement des combustibles recommandés

Utilizar sólo los combustibles recomendados

CO emissioni

CO emissions

CO emission

Emission de CO

Emisión de CO

Tensione/Frequenza nominale

Rated voltage/frequency

Spannung/Nennfrequenz

Tension/Fréquence nominale

Tensión/Frecuencia nominal

Temperatura dei fumi

Flue gas temperature

Abgastemperatur

Température des fumées

Temperatura de los humos

Leggere e seguire le istruzioni di funzionamento

Read and follow the operating instructions.

Lesen und befolgen Sie die Betriebsanleitungen

Lire et suivre les instructions de fonctionnement

Leer y seguir las instrucciones de funcionamiento

Potenza termica nominale

Rated heat output

Nenn-Heizleistung

Puissance nominale

Potencia térmica nominal

N° lotto:

230 V

 

Pellets - Granulé de bois

Cod:

CULT/6KW/UP/N

Emissioni polveri

Dust emissions

Emission poussières

Staubemmissionen

Emission de polbo

112,4 °C

CULT 6 kW UP

Matr:

000000

Pt

CO @ 13% O

Tf

18

50 Hz

325 W

6,3 kW

Nominal

Nominal

Ignition

48 W

Dust @ 13% O

n° DOP JM00182

the dop was drafted on the basis to the test report of accredited laboratory the accreditation

number of the laboratory is 2456 TÜV Rheinland Energy GmbH

80,7 mg/m

201,4 mg/m

3

Apparecchio per il riscaldamento domestico alimentato a pellet di legno - Residential space heating

appliance fired by wood pellet - Mit Holzpellets befeuerte Wärmeerzeuger für den Wohnbereich -

Appareil de chauffage domestique alimenté au pellet de bois - Aparato para calefacción domestica

alimentado con pellets de madera

Reduced

2,9 kW

Qtot

6,7 kW

Nominal

3,0 kW

Potenza bruciata

Burned power

Max Heizleistung

Puiss. max. disponible

Potencia quemada

93,5 %

95,1 %

Rendimento

Efficiency

Wirkungsgrad

Rendement

Rendimiento

Reduced

Nominal

Working

3

2

2

73,5 °C

Reduced

Reduced

17,3 mg/m

3 Nominal

Nominal
Reduced

B=100 mm

S=150 mm

L'apparecchio non può esser utilizzato in canna fumaria condivisa - The appliance can not be used

in flue shared - Das Gerät kann nicht im gemeinsamen schorustein verwendet werden - L'appareil

ne peut pas etre utilisè dans conduit partagè - El aparato no se puede utilisar en tubo de humos

compartido

F=900 mm

L000000

EN 14785:200

1

2

4

5

3

6

7

8

yy

Содержание AMBRIA2

Страница 1: ...SM122 EN REV06 2021_06 AMBRIA2 6 kW AMBRIA2 8 kW INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Pellet operated air heating stove AMBRIA2...

Страница 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Страница 3: ...CHAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDED FUELS 15 06 3 COMPONENTS 16 06 4 DIMENSIONS 17 CHAP 0...

Страница 4: ...more restrictive in this instance comply fully with the regulations prevailing in the country of installation all laws and local bylaws must be observed when installing and using the appliance includ...

Страница 5: ...old electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations for appliances fitted with g...

Страница 6: ...right to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER LIABILITY AND WARRANTY CONDITIONS Upon the delivery...

Страница 7: ...ensory or mental capabilities or lacking the experience or the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and on the understanding of...

Страница 8: ...ce with the laws and standards in force in the State Region or Area in which the machine is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly...

Страница 9: ...urs of operation shall be reset at the end of the Technical intervention and indicated on the Servicing Report 02 4 EQUIPMENT FOR OPERATORS AND MAINTENANCE PERSONNEL Every operator performing maintena...

Страница 10: ...03 2 LIFTING AND TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY REGULATIONS of this manu...

Страница 11: ...rective 2012 19 UE waste electrical and electronic equipment WEEE information for users The crossed out wastebasket symbol on the appliance means that at the end of its useful lifespan the product mus...

Страница 12: ...l with Display Wide backlit LCD display allowing operators to interface with the product set the operating parameters and receive work status data Timer controlled thermostat used to set the start up...

Страница 13: ...O Tensione Frequenza nominale Rated voltage frequency Spannung Nennfrequenz Tension Fr quence nominale Tensi n Frecuencia nominal Temperatura dei fumi Flue gas temperature Abgastemperatur Temp rature...

Страница 14: ...Switching on nominal power reduced power stand by 310 60 15 2 2 310 65 15 2 2 W Device mass 110 110 Kg Standard hopper capacity 15 15 Kg Flue draught Nominal heat output Reduced heat output 10 0 8 0...

Страница 15: ...use pellets that are very hard and with different dimensions the mechanical parts are sized and tested for use with pellets with the above mentioned characteristics No breakdown or malfunction depend...

Страница 16: ...r loading pellets 4 Emergency console 5 Firebox 6 Ash drawer 7 Combustion chamber door 8 Pellet hopper 9 Electronic control unit 10 Fume pressure switchi 11 Comburent air inlet tube 50 mm 12 Room temp...

Страница 17: ...17 ENGLISH 06 4 DIMENSIONS All measurements are in mm AMBRIA2 6 kW AMBRIA2 8 kW A 461 5 B 1073 C 487 8 AMBRIA2 6 kW AMBRIA2 8 kW C A B...

Страница 18: ...exhaust pipes and flue can be easily accessed for maintenance Fig 1 illustrates minimum distances that must be observed all measures must be in mm The lateral distance from the adjacent wall according...

Страница 19: ...re are deviations or curves for easier quicker and safer installation we recommend using double walled stainless steel pipes The use of pipes in fibre cement for connecting the equipment to the flue i...

Страница 20: ...hand the purchaser MUST assign all work to a qualified professional technician The device must be installed and used in accordance with all local and national laws and EC Regulations WARNING In the e...

Страница 21: ...opening needs to be designed in compliance with the specifications in paragraph 07 3 4 All models may be connected to the fume pipes with rear fume outlet Fig 1 For the construction of fume pipes plea...

Страница 22: ...force 2014 30 UE and 2014 35 UE WARNING Number Description 1 Radio control 2 Electronic card 3 Bipolar switch 4 Electric power cord with schuko socket 5 Smoke fan 6 Electrical heating element 7 Excha...

Страница 23: ...ontrol unit connected by radio frequency to the radio remote control manages all the device functions and the LCD display screen on the handheld console can be used to monitor all the stove operating...

Страница 24: ...ET ambient temperature which correspond to the automatic start up value of the stove In this condition the stove is not actually off but is waiting to turn back on if the above conditions are satisfie...

Страница 25: ...Wait until the appliance is completely cold on average 20 minutes 2 Unscrew the thermostat reset button lid on the back of the appliance see Fig 1 positions B 3 Press the button until you hear a CLIC...

Страница 26: ...hopper using a scoop Do not empty the sack directly into the hopper Check for obstructions in the flue and in the external air intake before starting the machine after a prolonged period of disuse Th...

Страница 27: ...use an ash vacuum not supplied with the stove but available from retailers and or specialised Technical Service Centers ORDINARY CLEANING THE INSTRUCTIONS BELOW REGARDING THE TIMING AND METHODS USED...

Страница 28: ...rnal walls and shaking it eventually Before replacing the firebox check there is no ash or dirt in the firebox housing Vacuum this area thoroughly too make sure residual ashes are cold Fig 8 Make sure...

Страница 29: ...Never spray detergents directly on cladding parts Fig 22 Use of abrasive and or corrosive chemical products can damage the painted parts and are reason for invalidation of the warranty on these parts...

Страница 30: ...into the domestic electrical system turn the switch to I see Fig 28 10 Pellet hopper loading Located on the rear part of the device the hopper is filled through an openable lid The hopper must be fill...

Страница 31: ...th special focus on horizontal segments Stove fume pass cleaning Cleaning of any deposits in the stove Cleaning of fans Check good ignition resistance operations Check electric electronic system integ...

Страница 32: ...at and pressure switch status and efficiency T Check the condition of the sealing gaskets paying special attention to the one on the closure of the combustion chamber door T Check the condition of the...

Страница 33: ...s safety pressure switch The stove does not start automatically The firebox is dirty preventing incoming air flow Clean it thoroughly and check it is clean each time you start it up The basket is posi...

Страница 34: ...34 NOTES...

Страница 35: ...35 ENGLISH NOTES...

Страница 36: ...SM122 EN REV06 2021_06 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...

Отзывы: