 CHAP.02  ACCIDENT PREVENTION / SAFETY REGULATIONS

 

02.1  

GENERAL CONSIDERATIONS

• 

The manual refers to essential aspects of the directives, regulations and dispositions on using the machine, summarising 

its most significant points.

• 

General legal regulations and mandatory rules regarding injury prevention and environmental protection must be 

observed. These obligations also include regulations regarding the use of personal protective equipment.

• 

For all work to be done on the system, the following dispositions and regulations in force must be observed regarding 

accident prevention, following the indications.

•  Before using the system the first time, the user must have read and understood the instruction manual perfectly and this 

chapter in particular.

• 

The user must also make sure that the machine is always in good condition as regards its safety requirements.

•  During  maintenance  and  inspection  activities,  wear  the  protective  garments  specified  in  following 

CHAP.02.4 - 

EQUIPMENT FOR OPERATORS AND MAINTENANCE PERSONNEL. 

Cleaning and maintenance activities 

may only be performed with the equipment cold and preferably disconnected from the power mains or with the main 

switch in the “O” position.

•  Danger warnings and signals in the form of plates, labels and markings must not be removed or made unidentifiable. If 

they are worn or broken, they must be replaced.

•  Modifications,  additions  or  transformations  must  not  be  made  on  the  machine  and  its  components  without  the 

manufacturer’s authorisation. This is valid first and foremost for installation and regulation of the installed safety devices. 

Failure to comply with this warning relieves the Manufacturer of all and any responsibility.

• 

Make sure, before starting up every time and after carrying out maintenance, that dismantled parts have been repositioned 

correctly and in particular all the protection devices that impede access to the machine.

 

02.2  

SAFETY REGULATIONS FOR ROUTINE MAINTENANCE AND USE

• 

The user and/or owner of the product is required, in accordance with the laws in force, to assign the installation and 

maintenance to qualified and specialised operators, and acknowledge the risks and hazards should they fail to observe 

this requirement. 

• 

Children of at least 8 years old, people with reduced physical, sensory or mental capabilities, or lacking the experience or 

the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and 

on the understanding of the deriving dangers. Children are not allowed to play with the device. Cleaning and maintenance 

are meant to be performed by the user and not by unsupervised children. 

•  The settings and programming of the product must only be performed by adults who have received suitable and specific 

training. Errors or incorrect settings can create hazardous conditions and trigger malfunctions with relative consequences 

for persons and things.

• 

Before any cleaning and/or routine or extraordinary maintenance on the machine, disconnect it from all energy sources; 

in particular, turn the electrical power switch to “O”.

• 

Prior to installation, the user and installer are obliged to check that the mains electrical supply to which the machine will be 

connected, corresponds to the voltage on the identification plate (see 

CHAP.05.2 - PRODUCT IDENTIFICATION

), 

and that it is equipped with all suitable safety devices to classify the electrical system as compliant with applicable safety 

standards. If this is not the case, contact a Qualified Technician to adapt the system to required standards.

• 

Upstream from the machine (at the user’s expense) on the electrical power supply line, a bipolar switch must be installed 

that is able to intercept all the current phases (see 

CHAP.06 - TECHNICAL DATA

).

• 

The irradiation area includes the area between the opening of the hearth and up to 0,9 metre of space frontally as well as 

laterally. No inflammable object must be left in this area (such as: inflammable liquids, fire-starting products or firewood, 

drapes, wooden decorations, rugs, etc.).

•  Do not use the stove to dry clothes, it could overheat and cause an outbreak of fire.
• 

ATTENTION - BEWARE OF BURNS

, most of the outer surfaces of the stove are very hot, door handle, glass, metal 

sides, majolica or metal top, fume exhaust pipe etc. Never touch the stove with naked hands when it is running; always 

use heat protection gloves, such as those supplied with the stove, when handling all parts.

• 

Before doing any internal cleaning or maintenance, you must wait until the machine reaches the ambient temperature.

•  If the stove is in alarm status due to a malfunction, do not attempt to restart it before finding out what has caused the heat 

generator to shut down.

• 

Never wash the internal parts of the combustion chamber with water.

Содержание AMBRIA2

Страница 1: ...SM122 EN REV06 2021_06 AMBRIA2 6 kW AMBRIA2 8 kW INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Pellet operated air heating stove AMBRIA2...

Страница 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Страница 3: ...CHAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDED FUELS 15 06 3 COMPONENTS 16 06 4 DIMENSIONS 17 CHAP 0...

Страница 4: ...more restrictive in this instance comply fully with the regulations prevailing in the country of installation all laws and local bylaws must be observed when installing and using the appliance includ...

Страница 5: ...old electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations for appliances fitted with g...

Страница 6: ...right to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER LIABILITY AND WARRANTY CONDITIONS Upon the delivery...

Страница 7: ...ensory or mental capabilities or lacking the experience or the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and on the understanding of...

Страница 8: ...ce with the laws and standards in force in the State Region or Area in which the machine is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly...

Страница 9: ...urs of operation shall be reset at the end of the Technical intervention and indicated on the Servicing Report 02 4 EQUIPMENT FOR OPERATORS AND MAINTENANCE PERSONNEL Every operator performing maintena...

Страница 10: ...03 2 LIFTING AND TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY REGULATIONS of this manu...

Страница 11: ...rective 2012 19 UE waste electrical and electronic equipment WEEE information for users The crossed out wastebasket symbol on the appliance means that at the end of its useful lifespan the product mus...

Страница 12: ...l with Display Wide backlit LCD display allowing operators to interface with the product set the operating parameters and receive work status data Timer controlled thermostat used to set the start up...

Страница 13: ...O Tensione Frequenza nominale Rated voltage frequency Spannung Nennfrequenz Tension Fr quence nominale Tensi n Frecuencia nominal Temperatura dei fumi Flue gas temperature Abgastemperatur Temp rature...

Страница 14: ...Switching on nominal power reduced power stand by 310 60 15 2 2 310 65 15 2 2 W Device mass 110 110 Kg Standard hopper capacity 15 15 Kg Flue draught Nominal heat output Reduced heat output 10 0 8 0...

Страница 15: ...use pellets that are very hard and with different dimensions the mechanical parts are sized and tested for use with pellets with the above mentioned characteristics No breakdown or malfunction depend...

Страница 16: ...r loading pellets 4 Emergency console 5 Firebox 6 Ash drawer 7 Combustion chamber door 8 Pellet hopper 9 Electronic control unit 10 Fume pressure switchi 11 Comburent air inlet tube 50 mm 12 Room temp...

Страница 17: ...17 ENGLISH 06 4 DIMENSIONS All measurements are in mm AMBRIA2 6 kW AMBRIA2 8 kW A 461 5 B 1073 C 487 8 AMBRIA2 6 kW AMBRIA2 8 kW C A B...

Страница 18: ...exhaust pipes and flue can be easily accessed for maintenance Fig 1 illustrates minimum distances that must be observed all measures must be in mm The lateral distance from the adjacent wall according...

Страница 19: ...re are deviations or curves for easier quicker and safer installation we recommend using double walled stainless steel pipes The use of pipes in fibre cement for connecting the equipment to the flue i...

Страница 20: ...hand the purchaser MUST assign all work to a qualified professional technician The device must be installed and used in accordance with all local and national laws and EC Regulations WARNING In the e...

Страница 21: ...opening needs to be designed in compliance with the specifications in paragraph 07 3 4 All models may be connected to the fume pipes with rear fume outlet Fig 1 For the construction of fume pipes plea...

Страница 22: ...force 2014 30 UE and 2014 35 UE WARNING Number Description 1 Radio control 2 Electronic card 3 Bipolar switch 4 Electric power cord with schuko socket 5 Smoke fan 6 Electrical heating element 7 Excha...

Страница 23: ...ontrol unit connected by radio frequency to the radio remote control manages all the device functions and the LCD display screen on the handheld console can be used to monitor all the stove operating...

Страница 24: ...ET ambient temperature which correspond to the automatic start up value of the stove In this condition the stove is not actually off but is waiting to turn back on if the above conditions are satisfie...

Страница 25: ...Wait until the appliance is completely cold on average 20 minutes 2 Unscrew the thermostat reset button lid on the back of the appliance see Fig 1 positions B 3 Press the button until you hear a CLIC...

Страница 26: ...hopper using a scoop Do not empty the sack directly into the hopper Check for obstructions in the flue and in the external air intake before starting the machine after a prolonged period of disuse Th...

Страница 27: ...use an ash vacuum not supplied with the stove but available from retailers and or specialised Technical Service Centers ORDINARY CLEANING THE INSTRUCTIONS BELOW REGARDING THE TIMING AND METHODS USED...

Страница 28: ...rnal walls and shaking it eventually Before replacing the firebox check there is no ash or dirt in the firebox housing Vacuum this area thoroughly too make sure residual ashes are cold Fig 8 Make sure...

Страница 29: ...Never spray detergents directly on cladding parts Fig 22 Use of abrasive and or corrosive chemical products can damage the painted parts and are reason for invalidation of the warranty on these parts...

Страница 30: ...into the domestic electrical system turn the switch to I see Fig 28 10 Pellet hopper loading Located on the rear part of the device the hopper is filled through an openable lid The hopper must be fill...

Страница 31: ...th special focus on horizontal segments Stove fume pass cleaning Cleaning of any deposits in the stove Cleaning of fans Check good ignition resistance operations Check electric electronic system integ...

Страница 32: ...at and pressure switch status and efficiency T Check the condition of the sealing gaskets paying special attention to the one on the closure of the combustion chamber door T Check the condition of the...

Страница 33: ...s safety pressure switch The stove does not start automatically The firebox is dirty preventing incoming air flow Clean it thoroughly and check it is clean each time you start it up The basket is posi...

Страница 34: ...34 NOTES...

Страница 35: ...35 ENGLISH NOTES...

Страница 36: ...SM122 EN REV06 2021_06 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...