background image

51

ENGLISH

Содержание AMBRIA

Страница 1: ...SM104 EN REV01 2015_07 AMBRIA and RIVA INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Pellet operated air heating stove Ambria Riva...

Страница 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Страница 3: ...L 11 04 2 DISPOSAL OF THE MACHINE 11 CHAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDED FUELS 15 06 3 CO...

Страница 4: ...appropriate This manual cannot be given to third parties for perusal without the written permission of Jolly Mec Caminetti S p A The technical directions for installation contained in this manual sho...

Страница 5: ...electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations for appliances fitted with gas...

Страница 6: ...ufacturer reserves the right to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER LIABILITY AND WARRANTY CONDI...

Страница 7: ...tted for children persons with acknowledged reduced psycho physical and sensory abilities and persons who lack experience in using such machines unless they are supervised by designated persons respon...

Страница 8: ...is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly prohibited The system installer MUST issue a Declaration of compliance for the work per...

Страница 9: ...EQUIPMENT FOR OPERATORS AND MAINTENANCE PERSONNEL Every operator performing maintenance on the machine must wear safety garments and personal protective equipment 1 Protection headphones 2 Gloves han...

Страница 10: ...TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY REGULATIONS of this manual and must wear...

Страница 11: ...ur and DO NOT disperse the packaging into the environment but take it to waste disposal centres for recycling All packaging can be recycled as it consists of wood polyethylene film polystyrene and car...

Страница 12: ...nd receive work status data Timer controlled thermostat used to set the start up and switch off times along with relative temperatures Ambient temperature setting and viewing of the current ambient te...

Страница 13: ...rned Jolly Mec did namely provide all of these documents in downloadable electronic form that you can easily see on the websiteoftheCompanyatthefollowingaddress http www jolly mec it it servizio clien...

Страница 14: ...minal thermal power at rated power 6 20 9 10 kW Reduced thermal power at reduced power 3 17 3 17 kW Yield at rated power 90 89 90 Yield reduced power 92 49 92 49 Flue gas temperature at rated power 10...

Страница 15: ...ts that are very hard and with different dimensions the mechanical parts are sized and tested for use with pellets with the above mentioned characteristics No breakdown or malfunction depending on the...

Страница 16: ...Pellet hopper 5 Ash drawer 6 Firebox 7 Combustion chamber door 8 Heating fan 9 Fume pressure switch 10 Electrical heating element for lighting 11 Pellet loading auger 12 Pellet loading auger gear mot...

Страница 17: ...17 ENGLISH 06 4 DIMENSIONS All measurements are in mm Ambria Riva A 483 505 B 897 1020 C 491 532 Ambria C A B Riva A B C...

Страница 18: ...e from inflammable material 1000 mm NOTE CHAP 07 POSITIONING AND CONNECTIONS FOR THE INSTALLER 07 1 SETTING UP OF EXTERNAL AIR INTAKES AND ELECTRIC CURRENT The device must only be installed indoors an...

Страница 19: ...re are deviations or curves for easier quicker and safer installation we recommend using double walled stainless steel pipes The use of pipes in fibre cement for connecting the equipment to the flue i...

Страница 20: ...rmance of the fume exhaust system is not excellent it is possible to adjust the operating settings of the stove to overcome draught defects by a maximum of 15 of the fume exhaust device this adjustmen...

Страница 21: ...ents The device is equipped with a power socket and fuse and a uniipolar switch In the event that the control unit does not switch on even after turning the switch to I ONE check that the fuse has not...

Страница 22: ...ESA 2 Electrical socket with uniipolar switch and fuse holder 4 CAVO 36 Electric power cord with schuko socket 5 VENT 13 Smoke fan 6 RESISTENZA 7 electrical heating element for lighting 7 VENT 14 Tang...

Страница 23: ...Electric power cord with schuko socket 5 VENT 13 Smoke fan 6 RESISTENZA 7 electrical heating element for lighting 7 VENT 15 Tangential exchange fan 8 TERMOSTATO 14 Pellet hopper bulb type safety therm...

Страница 24: ...l appliance functions and is controlled via a control display The electronic control unit features a timer function with customisable programmes and a user friendly operating settings Operations are c...

Страница 25: ...level from 1 to 5 Decrease output button Button to change page within the Menu Page forward 7 Display Displays the stove status messages 8 Component reference icons 9 DGT Indicator box Decal icon key...

Страница 26: ...t the electric element continues to run to perform the start up preheating phase 3 PELLET preloading after the preheating phase a set amount of PELLETS are delivered to the firebox to ignite the first...

Страница 27: ...ends on the output levels the higher the output level the faster the air will be pumped through the front grid Example of display message with the stove in RUNNING mode xxx WORK Example of display mes...

Страница 28: ...utton 4 to confirm 9 press button 1 or 2 to set STOP 1 time press button 4 to confirm 10 Set the operating power with buttons 1 or 2 Press button 4 to confirm 11 Set the required room temperature with...

Страница 29: ...appliance in RUNNING set DELAY TURN OFF to program shutdown The function is disabled when set to 00 00 Once the required delay is set press Key 4 to confirm the selection and open the next page With D...

Страница 30: ...pellet load time third row d phase in progress fourth row 3 press button 6 to change page 4 information for the assistance technician is provided from page 2 to page 5 5 press button 3 to exit press...

Страница 31: ...Y DISPLAY 1 button 4 press button 6 to reach the READ MEMORY page press button 4 to enter Menu 09 XXX TECHNIC YYY SETTINGS Menu with access key reserved for use by the Assistance Technician only Menu...

Страница 32: ...inutes the device will switch off The device will remain in STD BY until the ambient temperature reaches 1 C of the SET ambient temperature which correspond to the automatic start up value of the stov...

Страница 33: ...ws 1 Wait until the appliance is completely cold on average 20 minutes 2 Unscrew the thermostat reset button lid on the back of the appliance see Fig 1 positions B 3 Press the button until you hear a...

Страница 34: ...tly into the hopper The fireplace must be closed to prevent smoke from escaping The pellet hatch must be closed while the machine is running Check for obstructions in the flue and in the external air...

Страница 35: ...nd also the device s operating time The most suitable cleaning frequency can only be established a few days after use according to the actual amount of deposited residue and may vary from the interval...

Страница 36: ...e seat must be perfectly in line with the housing 3 Cleaning the combustion chamber and ash drawer daily The cleaning of the ash and combustion chamber should be made when the ash reaches the edge of...

Страница 37: ...n Fig 15 Move the central wall up and pull it toward yourself with the help of the door opening key Pull the central wall toward you until it will be blocked To complete the central wall removal with...

Страница 38: ...ner touches the other wall and then slip the wall off the stove Fig 26 To remove the left wall unscrew the screw placed near the brazier to ensure its correct placement Fig 27 28 29 If you have proper...

Страница 39: ...e procedure as for the right wall to remove the left wall Remove the two side supports by turning up Fig 34 35 36 37 after you have done this remove the down beat flame Fig 30 Fig 31 Fig 32 Fig 34 Fig...

Страница 40: ...Fig 38 39 Removed this piece the two rear walls are released to remove them simply take them off Fig 40 41 42 43 44 45 Even at this stage take the vacuum cleaner to clean the entire inner part of the...

Страница 41: ...state Do not reassemble broken or damaged parts may cause undesired operation of the stove WARNING Correctly replace the cup with the two placement points facing downwards Fig 50 WARNING 5 Pellet tan...

Страница 42: ...own of the stove The dirt the glass also depends on the quality and quantity of pellets used When this done always observe if the gray seal around the lass is in good condition if you fail to control...

Страница 43: ...the power socket Before connecting the plug on the cord supplied with the stove to the domestic electrical system plug it into the socket fitted on the back of the stove Fig 63 After plugging it into...

Страница 44: ...zontal segments Stove fume pass cleaning Cleaning of any deposits in the stove Cleaning of fans Check good ignition resistance operations Check electric electronic system integrity Check safety device...

Страница 45: ...the Technical Specifications see par 06 1 Low flue draught do not use the fireplace it could be dangerous carefully clean the flue the stove and the fume extractor Firebox is very dirty Switch off the...

Страница 46: ...ture is over 270 C Check the position of the fumes probe Check to see if the air exchange fan is running properly Check to see if the stove is dirty and clean it if necessary Check to see if the PELLE...

Страница 47: ...ped safety depressimeter Check to see if the combustion product exhaust duct is blocked Check the component is intact and the relative electrical connections correspond to the electrical wiring layout...

Страница 48: ...m is well ventilated Check that the slots on the back of the stove are clean to allow input of cooling air Contact the CAT if this type of alarm is tripped frequently AL16 SERVICE 24H The device conti...

Страница 49: ...49 ENGLISH NOTES...

Страница 50: ...50...

Страница 51: ...51 ENGLISH...

Страница 52: ...SM104 EN REV01 2015_07 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...

Отзывы: