14
All appliance tests, final inspection and fine-tuning was performed using the recommended certified pellets.. Jolly
Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of pellets that are not
recommended, as combustion parameters vary according to the quality of the pellets.
To achieve best operational results, it may be necessary to change the default factory settings on the control unit during the
“first start-up” commissioning phase. These operations must only be performed by the relative Technical Assistance Centre
(CAT), being the only operators authorised to complete the first start-up activities
WARNING
CHAP.06 TECHNICAL DATA
06.1 HOMOLOGATION
Technical specifications resulting from laboratory tests conducted according to EN 14785:2006 test methods at the CERTIFICATION
institute.
Description
Ambria 6 kW
Riva 6 kW
Ambria 9 kW
Riva 9 kW
UM
Thermal power introduced (at rated power)
6,82
10,12
kW
Thermal power introduced (at reduced power)
3,43
3,43
kW
Nominal thermal power (at rated power)
6,20
9,10
kW
Reduced thermal power (at reduced power)
3,17
3,17
kW
Yield (at rated power)
90,89
90
%
Yield (reduced power)
92,49
92,49
%
Flue gas temperature (at rated power)
104,6
135,4
°C
Flue gas temperature (at reduced power)
68,4
68,4
°C
Carbon dioxide at rated power
6,89
8,83
%
Carbon dioxide at reduced power
4,95
4,95
%
CO at 13% O
2
(at rated power)
140,8
219,7
mg/m
3
CO at 13% O
2
(at reduced power)
580,2
580,2
mg/m
3
Fumes speed (rated power)
6,9
8,0
g/s
Fumes speed (reduced power)
4,7
4,7
g/s
Min. and Max. draft
10 - 12
10 - 12
Pa
Pellets tank capacity
17
17
Kg
Pellet consumption (at rated power)
1,4
2,1
Kg/h
Pellet consumption (at reduced power)
0,7
0,7
Kg/h
Pellets autonomy (at rated power)
12
8
h
Pellets autonomy (at reduced power)
24
24
h
Air inlet diameter
48
48
mm
Fumes outlet diameter
80
80
mm
Voltage and frequency of power supply
230 - 50/60
230 - 50/60
V ac - Hz
Electrical power absorbed Min - Max
150 - 380
150 - 380
W
Weight of the stove
107 (Riva)
96 (Ambria)
107 (Riva)
96 (Ambria)
Kg
The declared output may vary according to fuel type.
The above technical specifications were measured with certified quality PELLETS. ONLY use this type of fuel as
recommended later in
CHAP.06.2 - RECOMMENDED FUELS
.