JET-7000 (Old) Console Engineering Mode Guide
I.
To set up the
system
parameters:
II.
To calibrate
the elevation .
u
(from 0 to 15%)
1
Press Slow, Down, and RESET keys
simultaneously to enter Engineering Mode.
2
While the display read "CAL-HI", press PROGRAM
INTERVAL. The display will show C1. Please
press Fast or Slow keys to set
C1,
and then press
Up key to set
C2-C6.(refer to table 1)
parameter value
memo
C1
35
For
ver0.3
35(British) 51(metric)
C2
125
C3
66
C4
50
C5
4
C6
1-89
Only for ver 0.3 max time
Table 1
3
Press POWER key to save.
1.
Press Slow , Down, and RESET keys
simultaneously. And the display reads "CAL-HI".
2.
While the treadmill raises to the maximum incline,
verify the grade should be 15% (30cm).
3.
Press the START/STOP key
, and the display reads
"CAL-LO".
4.
While the treadmill lower to the minimum incline,
verify the grade should be 0% (8~9cm).
Press the
START/STOP key to store.
4-1 Revision: 1.0 Date: 2001-06-01
Содержание JET 6000
Страница 1: ......
Страница 4: ...Revision 1 0 Date 2001 06 01 SECTION 1 MAINTENANCE PROCEDURE...
Страница 9: ...Revision 1 0 Date 2001 06 01 SECTION 2 IMPORTANT SAFETY INSTRUCTIONS...
Страница 11: ...Revision 1 0 Date 2001 06 01 SECTION 3 WIRING DIAGRAM INSTRUCTION...
Страница 15: ...Revision 1 0 Date 2001 06 01 SECTION 4 CONSOLE ENGINEERING MODE GUIDE...
Страница 21: ...Revision 1 0 Date 2001 06 01 SECTION 5 MCB LED INSTRUCTIONS...
Страница 27: ...Revision 1 0 Date 2001 06 01 SECTION 6 TROUBLESHOOTINGS...
Страница 39: ...SECTION 7 PARTS REPLACEMENT PROCEDURE Revision 1 0 Date 2001 06 01...
Страница 58: ...SECTION 8 SERVICE FORM Revision 1 0 Date 2001 06 01...