Heart-Rate-Control function does not work
Possible causes:
1.
Transmitter does not
contact with user's
chest very well.
2.
Transmitter(Polar-
belt) is at low battery
status.
3.
Transmitter(Polar-
belt) is damaged.
4.
Heart-rate-control
board is damaged.
5.
PCB is damaged.
Fix:
1.
Center the
transmitter on your
chest below the
pectoral muscle(breast)
as shown, then check again.
2.
Remove the battery cover of the transmitter.
Replace a new battery and check again.
u
Actually, as moisture may activate the
transmitter, please dry transmitter after use.
OR
3.
Transmitter is damaged.
Replace the Transmitter.
OR
4.
Heart-rate-control board is damaged.
Replace the Heart-rate-control board.
OR
5.
PCB is damaged.
Replace the PCB.
6-7 Revision: 1.0 Date: 2001-06-01