Error message on console
JET6000/7000N
Error
message
cause
solution
Err2
P0 P1 P2 P4 P5 have a wrong
parameter values
l
Re-calibrate all parameter
values in Engineering Mode
Err3
VR is open loop or short
•
Re-plug or replace the Incline
Motor
(Jet6000)
•
Re-plug or replace the
VR
(Jet7000)
•
Re-plug or replace the 8-pin
console cable
•
MCB or PCB is damaged
Err6
No elevating after press the “up”
or “down” key about 5 seconds
l
Re-calibrate the “P4, P5”
parameter values.
JET7000E
Error
message
cause
solution
Err2
EEPROM Checksum error
l
Re-calibrate all parameter
values in Engineering Mode
6-11 Revision: 1.0 Date: 2001-06-01