Date and time
After you press the
Date and Time
button, the Date and Time screen displays. Use the following
procedure to make changes.
Note:
To enter the date information, the format is: YYYY / MM / DD.
Figure 67: Date and time
1. Press the
Change
button.
2. Enter the correct date and time.
3. Press the
Set
button to set the time.
4. Press the
Start
button to restart the clock.
If the clock is not keeping the correct time, use the following to fix it:
1. Press the
Correct
button to specify a correcting amount (+ or -).
2. Press the
Set
button to update the time.
Operation switch
In this screen section, choices can be made about the mode of operation for the various devices.
Use the buttons to make your choice. The choices are:
Forced Dilution:
indicates whether forced dilution is ON or OFF.
Refrigerant Pump:
indicates whether the refrigerant pump is operating automatically (Auto mode)
or is stopped (Stop mode)
Purge Mode:
The
Auto
and
Manual
buttons control the purge operation. The lit button indicates if
the purge mode is Automatic or Manual.
Manual Purge:
The
ON
and
OFF
buttons control the manual purge operation. The lit button tells
you if the manual purge operation is running or not. If you press the Purge Mode
Auto
button, the
purge is done automatically. If you press the Purge Mode
Manual
button, the purge starts when
you press the Manual Purge
ON
button. The purge stops when you press the Manual Purge
OFF
button.
139
YHAU-C Single Effect Steam-Fired Absorption Chiller
Содержание York YHAU-C
Страница 2: ......
Страница 26: ...Figure 6 Fitting tir rollers to the machine YHAU C Single Effect Steam Fired Absorption Chiller 24...
Страница 33: ...Figure 11 Location of rupture disk 31 YHAU C Single Effect Steam Fired Absorption Chiller...
Страница 85: ...Figure 37 PLC and touch screen communication wiring 83 YHAU C Single Effect Steam Fired Absorption Chiller...
Страница 103: ...Figure 49 Cooling start diagram 101 YHAU C Single Effect Steam Fired Absorption Chiller...
Страница 104: ...Figure 50 Cooling stop diagram YHAU C Single Effect Steam Fired Absorption Chiller 102...
Страница 166: ...Figure 73 Steam and drain system YHAU C Single Effect Steam Fired Absorption Chiller 164...
Страница 167: ...Figure 74 Duhring diagram PTX chart F 165 YHAU C Single Effect Steam Fired Absorption Chiller...
Страница 168: ...Figure 75 Duhring diagram PTX chart C YHAU C Single Effect Steam Fired Absorption Chiller 166...
Страница 169: ...Figure 76 Specific gravity concentration F 167 YHAU C Single Effect Steam Fired Absorption Chiller...
Страница 170: ...Figure 77 Specific gravity concentration C YHAU C Single Effect Steam Fired Absorption Chiller 168...
Страница 178: ...Figure 79 Troubleshooting sequence flow chart YHAU C Single Effect Steam Fired Absorption Chiller 176...