www.johnsonandstarley.co.uk
14
10.
CONDENSATE PUMP & DRAIN TUBE
10.1
CONDENSATE PUMP
10.1.1 Supplied with 6mm x 10m condense tube. Condense adapter and 2 x
clips.
SAFETY NOTE:
If the pump fails, the safety float switch will shut off the heater
operation.
10.1.2 DO NOT HANDLE PUMP IN WET CONDITIONS OR WITH WET
HANDS
10.1.3 To reduce the risk of electric shock, ensure the electrical supply is perma-
nently wired to earth.
10.1.4 TECHNICAL DATA
a)
Tank capacity : 0.5L
b)
High level safety cut out
c)
Outlet size 6mm I.D.
d)
Maximum water temperature: 60°
e)
Maximum noise level: 21 dB(A) at 1m
10.1.5 Where the tubing from the pump is connected directly to the soil stack
or waste pipe, there must always be either a waste trap after the tubing
connections, or a 75mm ‘U’ trap formed within the tubing.
10.1.6 Where the tubing from the pump is connected to an external soil and
vent stack extra care is necessary to ensure that the condense pipe
could not be blocked through the condense freezing.
10.1.7 The tank pump uses small bore (6mm) flexible hose which can be routed
above or below doors, windows and under kitchen cabinets.
B
C
D
A
RESERVOIR
FLOAT
FILTER
FIGURE 11. CONDENSE PUMP
10.2
CONDENSE TUBE ROUTING OPTIONS
Option A.
Routing to outside drain via sink
Option B.
Routing to drain pipe via roof
Option C.
Routing to bath waste
Option D.
Routing under floor to sink waste
FIGURE 12. CONDENSATE ROUTING OPTIONS
NOTE:
7m MAXIMUM HEAD
LENGTH OF CONDENSE
TUBE
Содержание WARMCAIR C16D
Страница 29: ...29 Sales Spares Replacement Help Line 01604 762881 20 FAULT FINDING FLOW CHART...
Страница 42: ...NOTES...
Страница 43: ...NOTES...