SAFETY & GAS INFORMATION
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE COMMENCING WITH THE INSTALLATION
4.1
GENERAL SAFETY INFORMATION
4.1.1
Ensure the mains supply voltage, frequency, number of phases and power rating comply with details
on the rating label.
4.1.2
All wiring must be in accordance with the appropriate standards. The equipment must be supplied with
a double pole isolator switch.
4.1.3
Ensure safety regulations and practices are adhered to when installing and using this equipment.
4.1.4
The weight of this appliance exceeds that recommended for a one-man lift. It will therefore be necessary
to gain assistance at times during the installation procedure.
4.1.5
It should be noted that this appliance may contain sharp edges. Care MUST be taken when handling
the appliance to prevent injury.
4.1.6
Once the appliance has been fired beware that certain parts will be hot to the touch.
4.1.7
Do not install flues during rain, high winds or in severe weather conditions.
4.2
GAS INFORMATION
4.2.1 Gas Categories
a. The appliance is certified as a CAT I 2H (20) appliance.
4.2.2 Gas Supply
a. The gas installation must be completed in accordance with the relevant standards (BS 6891).
b. The supply must be capable of providing a steady inlet working pressure to the appliance of 20
mbar at a rate of 1.94m³/h or 52.64ft²/h (Calculated with a Gas C of 38.7MJ/m³)
c. The installation must be tested for gas tightness using suitable methods. The Pipework should
also be purged of air in accordance with the IG Publication Standard.
5.
TECHNICAL DATA
TABLE 1. C16D TECHNICAL DATA
C16D
WEIGHT
62kg
GAS
G20
GAS SUPPLY PRESSURE
20mbar
GAS CATEGORY
I 2H
COUNTRIES OF INSTALLATION
GB & IE
ELECTRICAL SUPPLY
230V ~ 50Hz fused 5A 215W
ELECTRIC POWER CONSUMPTION
100 W (at rated heating capacity), 27 W (at minimal cap.), 5 W (standby mode)
USEFUL EFFICIENCY
88 % (at rated heating capacity), 98 % (at minimum capacity)
ENVELOPE LOSS FACTOR
0
IGNITION BURNER POWER CONSUM.
0 W
EMISSIONS OF NITROGEN OXIDES
64 mg / kWh
EMISSION EFFICIENCY
87.52 %
SEASONAL SPACE HEATING ENERGY EFFIC.
76.2 %
MAXIMUM
MINIMUM
kW
MJ/h
Btu/h
kW
MJ/h
Btu/h
INPUT (GROSS)
16.0
57.6
54,592
5.0
18.0
17,060
OUTPUT
14.08
31.68
48,041
4.4
15.84
15,013
GAS RATE CV 1037Btu/FT³
1.94m³/h (52.64ft³/h)
0.466m³/h (16.45ft³/h)
BURNER % CO²
9 ± 1
8 ± 1