www.johnsonandstarley.co.uk
15
60/100 Flue Components
Description
Parts included
Application
Pt No
Pascal
Std flue kit (horizontal terminal)
1 x Boiler connection elbow.
Horizontal
1000-0018920
45
1 x Appliance seal.
1 x 60/80 adaptor.
1 x 800 mm horizontal terminal.
1 x 100 mm diameter clamp.
2 x EPDM wall cover plate.
1000 mm straight extension
1 x 1000 mm straight extension.
Horizontal
Vertical
1000-0018940
5
1 x 100 mm diameter clamp.
2 x screws.
500 mm straight extension
1 x 500 mm straight extension.
Horizontal
Vertical
1000-0018950
2.5
1 x 100 mm diameter clamp.
2 x screws.
250 mm straight extension
1 x 250 mm straight extension.
Horizontal
Vertical
1000-0018960
1.25
1 x 100 mm diameter clamp.
2 x screws.
Vertical terminal 1140 mm
1 x vertical terminal assembly.
Vertical
1000-0018930
5
1 x support bracket
Vertical Appliance Adaptor
1 x Adaptor
Vertical
1000-0018990
0
90° elbow
1 x Elbow
Horizontal
Vertical
1000-0018980
10
45° elbow
1 x Elbow
Horizontal
Vertical
1000-0018970
5
Flat Roof Weather Collar
1 x Aluminium circular flat roof seal
Vertical
1000-0014900
N/A
Pitched Roof Weather Collar
1 x Plastic & lead pitched roof seal
Vertical
1000-0014890
N/A
Fixing Bracket (5 Pack)
5 x clamps for 100 mm tube
Horizontal
Vertical
N/A
94
95
96
97
98
99
100
101
102
10
20
30
40
50
60
70
80
90
100 110 120 130
Flue Pressure Drop (Pascals)
Heat Input (%age)
Output in relation to flue resistance.
60/100 Concentric flue systems
Pa
Direction
Overall
Assembled
Flue Length
mm
Heat
input
%
42 Horizontal
450
100
45 Horizontal
800
99
90 Horizontal
9800
95
5
Vertical
1140
101.5
42
Vertical
8540
100
90
Vertical
17740
95
Table.3-3
Table.3-5