background image

www.johnsonandstarley.co.uk

ITEM

G.C. No.

PART No.

DESCRIPTION

QTY

ECONOMAIRE 32

1

E69625

1000-0521020

Wiring Harness

1

2

E80119

N320-0350005

Wiring Harness (air heater)

1

3

Heat Exchanger

1

N322-0350005

Heat Exchanger (from serial number 54000501)

1

4

E69627

1000-0520990

FDC & Limit Switch

1

1000-0522340

FDC & Limit Switch (from serial number 54000501)

1

5

E69623

N320-0145000

Filter Assembly

1

N322-0145000

Filter Assembly (from serial number 54000501)

1

6

E69629

A700-0702000

Complete Burner Assembly

1

N322-0702000

Complete Burner Assembly (from serial number 54000501)

1

7

E69630

1000-0708260

Main Burner injector (Polidoro Ref: AL270)

1

8

173 096

1000-0704810

Ignition Burner Assembly

1

9

E69631

1000-0520860

Air Pressure Switch

1

10

E69632

1000-0520830

Clock  Mechanism

1

11

E69635

1000-0708370

Ignition Burner Feed Pipe

1

1000-0708970

Ignition Burner Feed Pipe (from serial number 54000501)

1

12

E69638

N320-0505000

Electric Flame Control Device (S.I.T.)

1

13

1000-0708990

Igniter Lead

1

14

E69640

1000-0708190

Multifunction Control

1

15

245 514

1000-0515620

Thermista-stat

1

16

E69642

N320-0504000

Combustion Air Fan (SIFAN)

1

N310-0504005

Combustion Air Fan (SIFAN) (from serial number 54000501)

1

17

E69644

N320-0500000

Complete Electrical Panel

1

N322-0500000

Complete Electrical Panel (from serial number 54000501)

1

18

E80146

1000-0520850

Control Module

1

19

245 509

1000-0513820

Fuse T3.15A (anti surge)

1

20

245 542

1000-0515970

Capacitor 15µf

1

21

E69650

N320-0167000

Cabinet Door Assembly

1

N322-0167000

Cabinet Door Assembly (from serial number 54000501)

1

22

E76429

1000-0500375

Air Circulation Fan

1

23

381 712

1000-0705140

Ignition Burner Injector (No 36)

1

392935

1000-0701260

Ignition Burner Injector (No 27) (from serial number 54000501)

1

24

E69653

1000-1507310

Gasket

1

25

E95-494

S01159

Air Pressure Tube Kit

1

26

E80151

1000-2501050

Grommet

1

27

1000-0708410

12mm Flared Connector

1

28

E69656

1000-0505540

Electronics Box (Cleanflow)

1

29

E69658

A0186 x 0309

Cleanflow Filter Medium (pad)

2

30

E69662

1000-0708210

Gas Feed Pipe

1

1000-0708950

Gas Feed Pipe (from serial number 54000501)

1

31

E69666

1000-0708360

Gas Feed p
Pipe 

1

32

View Port Window (NOT AVAILABLE AS A SPARE)

1

33

E69648

1000-0520880

Reset Panel (Daughter Board)

1

INTEJAN WA

TER HEA

TER

34

244-876

S00284

Main Body Assembly (inc. baffle & spring clip)

1

36

E80155

1000-0521870

Wiring Harness

1

37

E69670

1000-0520920

Overheat Cut-Off Switch

1

38

E01686

A700-0700000

Complete Burner Assembly

1

N322-0700000

Complete Burner Assembly (from serial number 54000501)

1

39

E69640

1000-0708190

Multifunction Control

1

40

384 615

BOS 00562

Burner Arm

1

41

244880

BOS 02397/1

Ignition Burner Assembly

1

42

H50495

S01482

Thermostat

1

1000-0708930

Thermostat (from serial number 54000501)

1

43

E80158

1000-0702090

Main Injector Nozzle (Amal 187/001/400) 

1

44

392935

1000-0701260

Ignition Burner Injector (No 27)

1

45

E80159

1000-0708990

Igniter Lead

1

46

E69693

1000-0708240

Main Burner Gas Feed Pipe

1

1000-0708940

Main Burner Gas Feed Pipe (from serial number 54000501)

1

47

230 328

1000-2500070

Phial Retaining Plug

1

48

E69638

N320-0505000

Electronic Flame Control Device (S.I.T)

1

49

E69695

1000-0708400

Ignition Burner Feed Pipe

1

1000-0708960

Ignition Burner Feed Pipe (from serial number 54000501)

1

50

E69707

1000-0708200

Gas Feed Pipe

1

51

E80151

1000-2501050

Grommet

1

22.   LIST OF SPARES        

Telephone Johnson & Starley Spares Department

 01604 707012 

Содержание ECONOMAIRE 32

Страница 1: ...k Publication No ZZ 1088 12 April 2010 ECONOMAIRE 32 WARM AIR HEATER with Intejan Water Circulator INSTALLATION COMMISSIONING SERVICING INSTRUCTIONS G C NUMBERS Air Heater 42 416 14 Water Circulator 5...

Страница 2: ...nt for their needs that it is installed commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building...

Страница 3: ...for retro fit to the ECONOMAIRE 32 2 2 The air heater output can be adjusted between 7 3kW 26 4MJ h 25 000 Btu h and 9 4kW 33 8MJ h 32 000 Btu h summer air circulation of unheated air is available by...

Страница 4: ...n existing base duct warm air plenum always ensure that installation is carried out such that the rear left hand corner of the heater is aligned with the rear left hand corner of the base duct so that...

Страница 5: ...t size of return air grilles and ducting is used For heaters on maximum output the return air duct size should not be less than the equivalent of 250mm x 200mm 10 x 8 If flexible duct is used the duct...

Страница 6: ...larly under a balcony or immediately adjacent to a drain pipe 8 2 3 The terminal position must ensure that combustion products cannot enter the building in which the heater is installed or any adjacen...

Страница 7: ...From a vertical drain pipe or soil pipe 150mm H From an internal or external corner Greater than 450mm protrusion 300mm I Above ground roof or balcony level 300mm J From a surface facing the terminal...

Страница 8: ...al Terminal Support Bracket 1 1000 0014980 Terrcotta 7 Lead Pitched Roof Flashing Collar 1 1000 0014890 Anthracite 8 Lead Pitched Roof Flashing Collar 1 1000 0014990 Terracotta 9 Aluminium Flat Roof F...

Страница 9: ...chnical data paragraph 1 3 10 2 An independent gas supply pipe from the meter is to be preferred wherever possible Where this is not possible the pipe must be capable of taking the complete input of t...

Страница 10: ...green LED ON light on the indicator panel will illuminate After a period of approx 5 seconds the module will move on to stage 6 indicated by 6 on the LED NOTE Regardless of when the burner ignites dur...

Страница 11: ...chmark Checklist located on the inside back pages of this document prior to handing over the appliance to the occupier 11 6 SAFETY CHECK In order to check the correct operation of the control module r...

Страница 12: ...maintained you MUST ensure that flow and return pipes into the sealed compartment are sealed with the supplied grommets 12 2 WATER CONNECTIONS NOTE Both flow and return connections are Rp in BSP fema...

Страница 13: ...main burner SHOULD ignite and the igniter will stop 13 2 9 When the control module reaches stage 8 indicated by 8 on the LED power is fed to the gas valve and the green LED ON light on the indicator p...

Страница 14: ...ntrol thermista stat and the SUMMER AIRFLOW switch 14 2 4 That the time control must be reset following a power failure 14 2 5 How to use the circulator thermostat to set the water temperature 14 2 6...

Страница 15: ...nction control remove the relevant burner assembly fixing screws 15 2 7 Break the gas supply at the gas union and remove the gas feed pipe fixing screw 15 2 8 Whilst supporting the assembly carefully...

Страница 16: ...e cover plate screws 15 7 10 Re establish electrical supply 15 7 11 Commission air heater and water circulator as described in the relevant sections above 15 8 TIME CONTROL SWITCH AND LED INDICATOR DA...

Страница 17: ...embly as detailed at paragraph 15 2 15 11 5 Remove the multifunctional control for the water circulator IF FITTED 15 11 6 Release the 4 x screws securing the combustion chamber heat shield and withdra...

Страница 18: ...water circulator will override those for the air heater therefore LED displays 8 and 9 will override 5 and 6 For this reason it is strongly recommended that the air heater and water circulator be comm...

Страница 19: ...19 Telephone 01604 762881 FIGURE 12 CONTROL FLOWCHART 17 DIAGNOSIS FLOWCHARTS...

Страница 20: ...www johnsonandstarley co uk 20 FIGURE 13 AIR HEATER DIAGNOSIS FLOWCHART...

Страница 21: ...21 Telephone 01604 762881 FIGURE 14 CONTROL FLOWCHART...

Страница 22: ...www johnsonandstarley co uk 22 18 LOGIC DIAGRAM FIGURE 15 LOGIC DIAGRAM...

Страница 23: ...23 Telephone 01604 762881 3 19 SCHEMATIC DIAGRAM FIGURE 16 SCHEMATIC DIAGRAM...

Страница 24: ...www johnsonandstarley co uk 24 FIGURE 17 CIRCUIT DIAGRAM 20 CIRCUIT DIAGRAM Showing connections of an external controller...

Страница 25: ...25 Telephone 01604 762881 21 DIMENSIONS FIGURE 18 DIMENSIONS...

Страница 26: ...1 23 381 712 1000 0705140 Ignition Burner Injector No 36 1 392935 1000 0701260 Ignition Burner Injector No 27 from serial number 54000501 1 24 E69653 1000 1507310 Gasket 1 25 E95 494 S01159 Air Press...

Страница 27: ...27 Telephone 01604 762881 FIGURE 19 EXPLODED DIAGRAM 23 EXPLODED DIAGRAM...

Страница 28: ...from Johnson Starley Ltd Telephone the Sales Office for further information ECONOMAIRE 32 ANCILLARY S Description Product Code 1 Cleanflow Air Filter ECF32 2 Return Air Plenums RAP32 3 Side Return Ai...

Страница 29: ...29 Telephone 01604 762881 This Log Book should be filled out at each annual service ECONOMAIRE 32 LOG BOOK WARM AIR HEATER AND WATER CIRCULATOR COMMISSIONING CHECKLIST...

Страница 30: ...ty but does not affect statutory rights Customer Name Address Telephone Number Warm Air Unit Make and Model Warm Air Unit Serial Number Commissioned by print name Gas Safe Reg No Company Name Telephon...

Страница 31: ......

Страница 32: ...les Telephone 01604 707012 Fax 01604 764879 Service Telephone 01604 707011 Fax 01604 707017 Warm Air Upgrade Enquiry Service Telephone 01604 707026 Fax 01604 707017 COMMERCIAL INDUSTRIAL H V SOLUTIONS...

Отзывы: