Page 32
Turn the front surface of the Tool towards the back of the balancer, angle the plate towards
the scanner, approximately 5 degrees downward, then lock it in position using the pedal
brake.
Lower the wheel guard.
Press F6 to start calibration (foot pedal can be released).
The rear scanner will traverse to the right starting the calibration. If the difference between the
PULL index calculated by the user calibration and the value set by the factory calibration is
less than 0.5, the operation ends with a positive result and the text OK appears.
If the value is excessive, an error E400 (Pull index user calibration failure) is displayed and a
service technician should be notified. The balancer will how ever continue to function cor-
rectly for normal balancing procedures.
To exit press ESC.
The procedure is also described on the balancer display when the HELP key is pressed.
CAUTION:
Do not stand in a position that would allow the calibration tool to come
into contact with the users leg when released. Remain to the side and away when
releasing the tool from the locked position.