Page 36
11.0 MAINTENANCE
BEFORE ANY MAINTENANCE OR REPAIRS ARE ATTEMPTED THE MACHINE MUST BE DIS-
CONNECTED FROM THE ELECTRIC SUPPLY.
This balancer does not require any special maintenance, but the following precautions are required:
A.
Periodically clean all plastic parts with a glass cleaner. Wipe with a dry cloth.
B.
Clean all adapters regularly with a nonflammable liquid detergent all. Lubricate with a thin layer of oil.
C.
Periodically perform a routine shaft calibration as outlined on page 24 of this manual.
12.0 TROUBLE SHOOTING
TROUBLE
CAUSE
REMEDY
When turning the machine on,
No electric power
Check the input voltage
the displays do not light
Defect in the electric/electronic system
Call the Equiserv service center
for assistance
The machine gives random readouts.
Machine unstable on the floor
Check that machine is stable
Water in the tire
Remove water from tire.
Loose adaptor
Tighten the adaptor firmly
Defective electronic board
Call the Equiserv service center
for assistance
The machine does not stop after
Defective electronic component
Stop using the machine immedi
balancing cycle
ately and call the Equiserv service
center for assistance
The balancer is slow to display when
This machine performs a self-test routine
This is a normal characteristic
powering machine up.
on start-up. There will be a delay of several of the machine
seconds before the display is activated.
If the balancer ceases to
Malfunction of one of the scanners,
Call the Equiserv service center
properly measure parameter
A failure of the AWP system,
for assistance
values
or harness connection failure.