9.0 USER CALIBRATION
The BFH 1000 Balancer features a user calibration program
which requires only a few minutes to complete. Perform this
procedure when the balancer has been moved, disturbed, or
whenever accuracy is questioned. Occasional field calibration
will ensure years of reliable service.
Follow these 3 simple steps for shaft calibration:
1.
Press and release the
“Function”
key (F1) from the “Wel-
come or Main Screen”.
2.
Press and release the
“Calibration”
key (F1). Fig 53.
3.
Place 2 cones followed by the clamping nut (no retainer)
onto the shaft. Lift the pedal to clamp. See Figure 54.
4.
Lower the wheel guard and press the “
SPIN
” key. The bal-
ancer should spin and come to a complete stop. See Fig-
ure 55.
4.
After the balancer comes to a stop raise the wheel guard
and screw the calibration slug into left side of the flange
plate. Lower the wheel guard and press the “
SPIN
” key.
The balancer should spin and come to a complete stop.
Once the shaft stops the display should display “OK” and
the speaker sounds the Snap-on “TüDüLü”.See Figure 56.
SHAFT CALIBRATION IS COMPLETE
Figure 53
Figure 54 - 2 cones & clamping nut only
Figure 55
Figure 56