For Service Technician Use Only
COMPONENT TESTING
3-10
n
JennAir Built-in Coffee System
Component Testing Chart (Continued)
COMPONENT
FROM
TO
VOLTAGE
RESISTANCE NOTES
Power In (Main
Board)
Main Board - F3
(L1)
Main Board - F5
(N)
120 VAC
N/A
Main Board AC in
Power In (LED
Fan PCB)
LED Fan - F1 (L1)
LED Fan - F2 (N)
120 VAC
N/A
LED Fan PCB AC in
Pump
L1 Junction Block Main Board -
J1-4
120 VAC
6.2 ohms
Note polarity - Positive side
is connected to J1-4. If meter
leads are reversed, the coil
will show open.
NTC, Coffee
Main Board - J6
Main Board - J6
90K ohms
Room Temperature
NTC, Steamer
Main Board - J12
Main Board - J12
112K ohms
Room Temperature
Water Level Sensor
Main Board - J2
Main Board - J2
Continuity
Reed switch located at
bottom of water tank. This is
in series with the Water Tank
Switch.
Switch M1, Group
Infusion,Upper
Main Board - J4-1 Main Board -
J4-3
Continuity
On top of diverter assembly,
next to grinder motor.
Switch M2, Group
Infusion, Lower
Main Board - J5-1 Main Board -
J5-2
Continuity
Located behind the drive
motor for diverter.
Switch M3, Coffee
Grounds Container
Main Board - J5-3 Main Board - F2
Continuity
Coffee grounds container
removed = open circuit,
if container installed =
continuity 3-wire switch
located behind main board.
Switch M4, Service
Door
Main Board - J1-6 Main Board - F7
Continuity
*Service door closed =
continuity, door open = open
circuit. 3-wire switch located
behind main board.
Switch M5, Carafe
Presence
Main Board - J4-3 Main Board -
J4-5
Continuity
Located behind the hot water
dispenser tube.
Switch M6, Hot Water
Dispenser
Main Board - J4-3 Main Board -
J4-7
Continuity
Located behind the hot water
dispenser tube.
Switch M7, Water
Tank
Main Board - J2-1 Main Board -
J2-2
Continuity
This switch is located above
the water tank at rear of
coffee system. This switch is
in series with the Water Level
Sensor.
Switch M8, Standby
(Momentary)
Display/UI PCB
Display/UI PCB
Continuity*
*Reads continuity only when
switch is depressed.
Switch, Power
Switch-pin 1
Switch - pin 0
Continuity
Switch Open = Infinity,
Switch closed = < 3 ohms
NOTE:
When each switch is activated, the control will beep (sound a tone).
Содержание W11356996
Страница 1: ...SERVICE MANUAL Built in Coffee System W11356996...
Страница 4: ...iv n JennAir Built in Coffee System Notes...
Страница 20: ...For Service Technician Use Only DIAGNOSTICS TROUBLESHOOTING 2 8 n JennAir Built in Coffee System Notes...
Страница 34: ...For Service Technician Use Only COMPONENT TESTING 3 14 n JennAir Built in Coffee System Notes...
Страница 36: ...COMPONENT ACCESS 4 2 n JennAir Built in Coffee System Coffee System Exploded Views 1 2 3 4 5 6 7 8 9 10 11 7...
Страница 62: ...JennAir Built in Coffee System W11356996...