COMPONENT ACCESS
JennAir Built-in Coffee System
n
4-21
Removing the Coffee Heater and Mechanical Valve
1.
Complete the steps
from
“Removing the Top Panel and
Fan Panel”
.
2.
Complete the steps
from
“Removing the Back Panel and
Side Panel”
, prior to performing the following steps.
3.
Remove the wires connected to the upper micro-switch.
Unclip the hose coming from the pump/dumper.
4.
Remove four bolts (one at each corner). Take care as nuts are
on the underside of the assembly and may fall inside the unit.
5.
Lift up and remove the generator and mechanical valve
assembly.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.