background image

6

Cabinet Dimensions

IMPORTANT:

If installing a range hood or microwave hood

combination above the cooktop, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.

A.

24" (61.0 cm) minimum

B.

Combustible area above countertop (shown by dashed
box above)

C.

30" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered wood or metal cabinet
(24" [61 cm] minimum clearance if bottom of wood or
metal cabinet is covered by not less than 1/4" [6.4 mm]
flame retardant millboard covered with not less than No.
28 MSG sheet steel, 0.015" [0.04 mm] stainless steel, or
0.024" [0.06 mm] aluminum or 0.020" [0.05 mm] copper)

D.

13" (33 cm) recommended upper cabinet depth

E.

2

1

/

2

" (6.35 cm)

F.

19

5

/

16

" (49.0 cm) minimum, 19

3

/

8

" (49.3 cm) maximum

G.

18" (45.7 cm) minimum clearance from upper cabinet to
countertop within minimum horizontal clearances to
cooktop

H.

Grounded outlet: locate within 12" (30.5 cm) of right rear
corner of cutout

I.

23

1

/

2

" (59.7 cm) minimum, 23

5

/

8

" (60.0 cm) maximum

J.

5" (12.7 cm) minimum distance to nearest left and right
side combustible surface

K.

3" (7.62 cm) minimum distance to rear combustible
surface

L.

Gas line opening - wall: anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: anywhere within
6" (15.2 cm) of rear wall is recommended

M.

24

13

/

16

" (63.0 cm) minimum countertop depth is required

NOTE:

After making the countertop cutout, some installations

may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.

If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened
to avoid interfering with the regulator.

Electrical Requirements

General Information

This appliance must be supplied with the proper voltage and
frequency and connected to an individual, properly grounded
branch circuit, protected by a circuit breaker or fuse having
amperage as noted on the rating plate. We recommend you have
the electrical wiring and hookup of your cooktop connected by a
qualified electrician.

After installation, have the electrician show you where your main
cooktop disconnect is located. Check with your local utilities for
electrical codes which apply in your area. Failure to wire your
cooktop according to governing codes could result in a hazardous
condition.

If there are no codes, your cooktop must be wired and fused to
meet the requirements of the National Electrical Code,
ANSI/NFPA No. 70 - Latest edition.

You can get a copy by writing:

National Fire Protection Association

Battery march Park

Quincy. MA 02269

In Canada your cooktop must be wired and fused to meet the
requirements of the Canadian Electrical Code, CSA C22.1-02.

Be sure the installation of this product in a mobile home conforms
with the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280.

If this standard does not apply, you must follow the standard for
Manufactured Home Installations, ANSI A225.1 and
Manufactured Home Installations, Sites and Communities and
ANSI/NFPA 501A or with local codes.

You can get a copy of the Federal Standard by Writing:

Office of Mobile Home Standard HUD Building

451 7th Street, S. W.

Washington, D.C. 24010

Electrical Connection

An adequate electrical supply and outlet must be used to operate
the electrical parts of your cooktop.

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

IMPORTANT:

For personal safety, this appliance must be properly

grounded.

Содержание JGCK424PS

Страница 1: ...ectrical Requirements 6 Gas Supply Requirements 7 INSTALLATION 8 Prepare Cooktop for Installation 8 Install Cooktop 8 Make Gas Connection 9 Complete Installation 11 GAS CONVERSIONS 11 Low Flame Height...

Страница 2: ...ore gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do no...

Страница 3: ...in types of glass glass ceramic ceramic earthenware or other glazed utensils are suitable for range top service without breaking due to the sudden change in temperature Utensil Handles Should Be Turne...

Страница 4: ...or paper towels Cleaning Method Rinse with clean water and dry with soft lint free cloth Warm soapy water a mild detergent COOKTOP CONTROLS To avoid damage to the cooktop controls do not use steel woo...

Страница 5: ...est edition or with local codes IMPORTANT For solid surface material installations such as Surel and Corian consult with solid surface manufacturer Apply heat reflective tape such as Scotch Aluminum F...

Страница 6: ...d to avoid interfering with the regulator Electrical Requirements General Information This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grou...

Страница 7: ...as supply to regulator are the responsibility of the installer owner A B C D A Appliance pressure regulator B Flare union adaptor C Gasket D Appliance NOTE Use TEFLON tape rated for gas applications a...

Страница 8: ...oroughly before you begin Install Cooktop Step 1 Before installing apply the foam tape A tape is provided to seal the cooktop edges to the countertop Apply tape near inner underside cooktop edge Use t...

Страница 9: ...ulator and the shutoff valve to complete the connection 6 Assure all pipe joint connections are gas tight 7 Check alignment of valves after connecting the cooktop to the gas supply to be sure the mani...

Страница 10: ...ss unit is direct vent No Appliance Mounted Below This Cooktop A B C E F G H I D A Manifold entrance B Gasket C Flare union adaptor D Appliance pressure regulator supplied observe directionality of ga...

Страница 11: ...not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit WARNING Explosion Hazard Use a new CSA Internat...

Страница 12: ...ormed 1 Turn manual shut off valve to the closed position A B C A To cooktop B Shut off valve closed position C Gas supply line 2 Unplug cooktop or disconnect power 3 Replace all injectors as shown in...

Страница 13: ...ncrease 5 Replace control knob when adjustment is completed Low flame adjustment One or two rings flame A A Valve stem Counterclockwise to increase flame size Clockwise to reduce flame size Proper adj...

Страница 14: ...make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure...

Страница 15: ...ces instructions peut causer un incendie ou une explosion qui pourrait entra ner des dommages mat riels des blessures ou la mort Ne pas remiser de l essence ou tout autre liquide ou vapeur inflammabl...

Страница 16: ...uerait l air vers cet appareil de cuisson gaz Ce type de syst me de ventilation peut causer des probl mes d allumage et de combustion avec cet appareil de cuisson et entra ner des blessures corporelle...

Страница 17: ...ace de cuisson Pour viter le risque de br lures d inflammation des mati res inflammables et d claboussures dues un contact non intentionnel avec l ustensile la poign e d un ustensile doit toujours tre...

Страница 18: ...l eau propre et s cher avec un chiffon doux sans charpie Eau ti de et savonneuse d tergent doux COMMANDES DE LA TABLE DE CUISSON Afin d viter d endommager les commandes de la table de cuisson ne pas u...

Страница 19: ...les dispositions des codes locaux Au Canada l installation de cette table de cuisson doit satisfaire aux stipulations de la version la plus r cente de la norme CAN CSA Z240 ou des codes locaux en vig...

Страница 20: ...ur de 24 13 16 po 63 0 cm ou plus est n cessaire REMARQUE Apr s le d coupage de l ouverture dans le comptoir il est possible que pour certaines configurations d installation il soit n cessaire d entai...

Страница 21: ...sion Utiliser une canalisation neuve d arriv e de gaz approuv e par la CSA International Installer un robinet d arr t Bien serrer chaque organe de connexion de la canalisation de gaz En cas de connexi...

Страница 22: ...fectu s par un technicien qualifi avant d essayer de faire fonctionner la table de cuisson avec ce gaz Le gaz doit tre fourni au d tendeur de l appareil une pression comprise entre 6 po 15 24 cm et 14...

Страница 23: ...ment Raccordement au gaz AVERTISSEMENT Risque d explosion Utiliser une canalisation neuve d arriv e de gaz approuv e par la CSA International Installer un robinet d arr t Bien serrer chaque organe de...

Страница 24: ...aux l interdisent un nouveau connecteur m tallique flexible certifi A G A peut tre utilis pour raccorder cet appareil son alimentation en gaz Le connecteur doit avoir un diam tre interne au moins gal...

Страница 25: ...r t du gaz I Tuyau de 1 2 po 12 7 mm NPT tuyau d alimentation fixe Four mural mont dans l armoire sous la table de cuisson A B C F G H I J E D A Entr e de la tubulure de distribution B Joint d tanch i...

Страница 26: ...responsabilit de l installation correcte de cet ensemble L installation ne peut tre consid r e comme ad quate et compl te qu apr s contr le satisfaisant du fonctionnement de l appareil converti confo...

Страница 27: ...B C D A Vis du r partiteur de gaz du br leur pour faire mijoter B Vis du couvercle de l injecteur C Injecteur D Injecteur Apr s le remplacement des injecteurs r gler la flamme du br leur voir la secti...

Страница 28: ...r leur allumer REMARQUE Si le br leur ne s allume pas dans les cinq secondes teindre le bouton et attendre une minute avant de r essayer Cet appareil est exp di de l usine avec les r glages de flamme...

Страница 29: ...prolong e les br leurs de surface peuvent tre allum s manuellement Tenir une allumette allum e pr s d un br leur et tourner le bouton de r glage du gaz sur HI lev jusqu ce qu il s allume puis tourner...

Страница 30: ...n cessaire pour le nettoyage ou l entretien 1 D brancher l alimentation 2 Couper l alimentation en gaz 3 D brancher le raccord en acier inoxydable souple 4 D sinstaller les brides de fixation 5 l aid...

Страница 31: ...NOTES...

Страница 32: ...2023 All rights reserved Used under license in Canada Tous droits r serv s Utilis sous licence au Canada W11672254A 07 23...

Отзывы: