10
If a flexible connector is used assure that both the appliance
pressure regulator and manual shut-off valve are joined solidly to
other permanent hard piping (either gas supply or the appliance
manifold) so as to be physically stationary. See figure.
IMPORTANT:
Do not attempt to attach the flexible connector
directly to an external pipe thread.
Connection requires flare union adapters.
For Massachusetts Installations:
1.
Shut-off valve must be a “T” handle gas cock.
2.
Flexible gas connector must not be longer than
36" (91.44 cm).
3.
Not approved for installation in a bedroom or a bathroom
unless unit is direct vent.
No Appliance Mounted Below This Cooktop
A
B
C
E
F
G
H
I
D
A.
Manifold entrance
B.
Gasket
C.
Flare union adaptor
D.
Appliance pressure regulator, supplied (observe
directionality of gas flow)
E.
Flare union adaptor
F.
Flexible appliance connector 5 ft maximum (1.52 m)
maximum
G.
Flare union adaptor
H.
Gas shut-off valve
I.
1/2" (12.7 mm) NPT pipe (stationary supply pipe)
Wall Oven Mounted In Cabinetry Below This Cooktop
A
B
C
F
G
H
I
J
E
D
A.
Manifold entrance
B.
Gasket
C.
1/2" (12.7 mm) NPT pipe nipple elbow
D.
Flare union adaptor
E.
Flexible appliance connector 5 ft maximum (1.52 m)
maximum
F.
Flare union adaptor
G.
Appliance pressure regulator, supplied (observe
directionality of gas flow)
H.
1/2" (12.7 mm) NPT pipe nipple
I.
Gas shut-off valve
J.
1/2" (12.7 mm) NPT pipe (stationary supply pipe)