29
4.3
Spin the wheel to the left to the position defined in point 4.1 until the closest spoke reaches
the vertical position. To accept the position press button
. The computer shall save the
wheel position as a position of sticking the first correction weight. The indicator screen shall
display “Pt-2”, i.e. it is necessary to start searching for a point of sticking another correction
weight.
4.4
Spin the wheel to the right to the position defined in point 4.3 until the closest spoke
r
eaches the vertical position. To accept the position press button
.
It is a position in which the correction weight of 25 g should be stuck.
4.5
Spin the wheel to the left to the position set in point 4.1. The moment of reaching proper
position of the wheel is signalled by a sound, displaying of values of imbalance and arrows
directed toward one another.
It is a position in which the correction weight of 18 g (20 g) should be stuck.
4.6
After sticking correction weights exit the programme
3P
by pressing button
STOP.
Initiate
the measuring cycle and check if the wheel has been properly balanced.
CALIBRATION WITH THE CALIBRATION DEVICE
The wheel balancer is equipped with a self-calibration system enabling the user to tune the
machine on its own. Calibration shall be performed in the case of suspicions of incorrect
indications displayed by the machine (caused by aging of electronic components, impact of
temperature, vibrations in transport, etc.). Calibration of the wheel balancer should be carried
out in the following manner:
1. Parameters of setpoints corresponding to parameters of the wheel rim, i.e.
-distance
- diameter
18.0;
- width
5.0, s1 are entered automatically.
2. Mount the calibration device onto the shaft so that the hole of the device is positioned
opposite the red pin (2) attached on the shaft.