JCM Part No. 960-000076R_Rev. 1
© 2007, JCM-American Corporation
A - 11
Troubleshooting
World Bill Acceptor (WBA®-1x/2x -SS & SS2)
Appendix A
Abnormal Error Code Table
Table A-10 lists the WBA-1X/2X Abnormal Operation Codes.
Table A-10
WBA-1X/2X Abnormal Operation Code Table
Abnormal Codes
Flash
Error
Count
Description
Possible Cause
Follow-up Test
(Refer to Table A-5)
1
Cash Box Full
Stacker Encoder
Test #3-Stacking, #7 Transport
Sensors
2
Stacker Jam or Pusher Unit Trouble Stacker Encoder or Pusher Home
Sensor (S1)
Test #3-Stacking, #7 Transport
Sensors
3
Transport Cover Open or Solenoid
Lever Trouble
Transport Entrance Sensor or
Solenoid Lever Sensor
Test #7-Transport Sensors
4
Blocked Bill Path Sensor
All Head and Transport Sensors
Test #6-Head Sensor, Test #7
Transport Sensors
5
The Acceptance Head Detached,
not Calibrated or Incorrect Type
Clean and Calibrate; Check All
Head Sensors and Head
Detached Test
Test #6-Head Sensor, Test #7
Acceptance Head Detached
6
Transport Motor Trouble or the
Signal is NOT being sent from the
Encoder Sensor
Transport Motor or Transport
Encoder
Test #1-Transport Motor, Test #7
Validator encoder Sensor
7
Reserved
N/A
N/A
8
Solenoid Lever Trouble
Lever Assembly, Lever Sensor
Test #5-Solenoid Test, Test #7
Solenoid Lever Sensor
10
Cash Box NOT Fully Seated
Cash Box Sensor (S2)
Test #7 Cash Box Sensor
11
Reserved
N/A
N/A
12
Reserved
N/A
N/A
Table A-11
WBA-1X/2X Test Mode 4 Abnormal Operation Code Table
Abnormal Codes Test Mode 4 ONLY from Table A-5
Flash
Error
Count
Description
Possible Cause
Follow-up Test
(Refer to Table A-5)
2
Solenoid Lever Trouble
Solenoid Sensor or Lever Jam Test #5-Solenoid, #7 Solenoid Lever Sensor
3
Blocked Head Sensor
Clean and Calibrate Head
Sensor
Test #6-Acceptor Head Sensors
4
Blocked Transport Sensor
Transport Sensors
Test #7-Transport Sensor Test
5
Cash Box Full
Stacker Encoder
Test #3-Stacker Test, #7 Stacker Encoder
Sensor
6
Pusher Unit Trouble in the
Cash Box
Stacker Encoder or Pusher
Home Sensor
Test #7-Stacker Encoder, #7 Stacker Home
Sensor
7
Acceptor Head Detached,
Not Calibrated or Wrong
Type
Clean and Calibrate; Check All
Head Sensors and Head
Detached Test
Test #6-Head Sensors, #7 Acceptor Head
Detached
Test Mode 4 Only Error Table
Table A-11 lists the WBA-1X/2X Abnormal Operation Codes.