This area can be used to import the software for the Sparx 18/30, see „7.3 Software update“
The colour portion in the light beam changes at the same time. Ensure that at least one colour
value always remains at 100%, as otherwise, the total brightness will be reduced. You can set
this in SKAL ALL. X/Y readjustment on the Sparx 18/30 is therefore deactivated. The current
white balance is also retained during the reset to factory settings. The white balance can be used
to change the basic relationship of the RGBW channels to each other. This affects both the col-
our wheel channel and the RGB channels. If a colour’s intensity has been changed significantly
using the FINE ADJUST menu, for example, the preset colours on the colour wheel channel are
no longer correct.
Zoom
The zoom range is calibrated in the factory. If the spotlight loses this calibration, the optics of the
Sparx 18/30 can be readjusted using the offset.
7.2 Cleaning the device
You should check the function of the fans in the head and foot at regular intervals. Above all,
make sure that the air intakes and the interior of the Sparx 18/30 are free of fluff and dust.
To do this, open the fan cover on the head (4x Phillips head screws with bayonet fastener) and the
base plate on the foot. You can now clean the Sparx 18/30 with a brush and a vacuum cleaner.
ATTENTION:
Disconnect the device from the mains and allow to cool for at least 10 minutes!
When looking directly into the light source, use welder’s goggles with weakening 4-5!
!
7.3 Software update
The Sparx 18/30 can be updated via a USB stick with micro-USB connection. To do this, copy
the file directly into the root directory of the USB stick. Then press and hold the right key below
the display. Now insert the Sparx 18/30 as soon as the message “Insert USB stick” appears on
the display and release the key. Now plug in the USB stick on the back of the device below the
signal connections and follow the instructions on the display. The Sparx 18/30 completes the
software update with a reset. You will find the latest software on our homepage.
7.4 Testing of electrical equipment
According to the German Social Accident Insurance (DGUV) Regulation 3 / Regulation 4, elec-
trical systems and equipment must be subjected to regular inspections. The fixing screw of the
DMX 5-pin socket can be used as measuring point for insulation and residual current measure-
ment. The screw is connected to all sheet metal parts via a contact washer.
PE measuring point