- 19 -
18
/
4.8 Shortcuts - quick operation
Pressing the ESC and DOWN keys in the main menu logs the spotlight out of the programmed
Lumen radio wireless transmitter. The spotlight is now ready to log in to another transmitter.
The following temperatures are also displayed:
TEMP BASE LCD
, the temperature on the display board
TEMP BASE PS
, the temperature of the power supply unit
TEMP BASE AIR
, the air temperature in the foot
TEMP HEAD PCB
, the temperature of the head board
TEMP HEAD DRV
, the temperature of the LED driver board
TEMP HEAD LED
, the average temperature of the LEDs
TEMP HEAD LEDs
, the individual temperatures of the LEDs
Both the current temperature and the maximum temperature are displayed. The maximum tem-
peratures can be individually deleted.