2.  Travel limit setting Opening & closing force self-learning 

 

 

 

 

NOTE

 

 Later model openers   

may have 

S

 in place of 

SET

C

 in place of 

CODE

+

 in   

Place of 

UP

 and 

-

 in place of   

DOWN

   

 

 

 

 

 

 

 

 

3.  Safety reverse force adjustment 

 

 

 

 

NOTE

 

 Later model openers   

may have 

S

 in place of 

SET

C

 in place of 

CODE

+

 in   

Place of 

UP

 and 

-

 in place of   

DOWN

   

 

  Press and hold 

SET

 button for 3 seconds until the LED flashes 

“1”

.  Press 

SET

  button  again  for  1  se

cond  .  “1”

  should  now 

display as steady (not flashing). 

  Adjust  the  open  limit  by  pressing  and  holding  the 

UP

  button. 

When  the  door  is  near  it

s  intended  open  position  release  the 

button and fine-tune the open position by momentarily pressing 

the 

UP

 and 

DOWN

 to determine the final open limit position, 

then press 

SET

” bu

tton, the display will show 

“2”

 

  NOTICE 

  Be  sure  not  to  set  the  open  limit  too  far  as  this 

can cause the door to overtravel and come out of the tracks 

or torsion cables to become loose

.   

  Now adjust the close limit by pressing and holding the 

DOWN

   

button. When the door is near it

s intended close position release 

the button and fine-tune the position by momentarily pressing the 

UP

  and 

DOWN

  buttons  to  determine  the  final  close  limit 

position, 

then press “

SET

 

If the opener stops and displays 

H

 or 

C

, this indicates 

there

s no hall signal or the opener is overloaded. Call a Service 

Technician. 

The opener will now operate a cycle automatically to remember 

the limit positions and the original opening & closing force, 

then return to standby mode. 

During learning, if the door stops unusually, and flashes 

H

C

O

L

 for 5 seconds, this indicates there

s no hall 

signal, overload, overtime or an incorrect limit setting. 

Press and hold 

SET

 button for 3 seconds until the LED 

flashes 

1

. Press 

UP

 until LED flashes 

2

, then press 

SET

  button.  The  display  is  now  in  force  adjustment 

mode. The LED displays the current set force value. 

Press  “UP”

  button  to  increase  the  force  an

d  “DOWN” 

button to decrease the force value. The maximum force 

is 

9  and  the  minimum  is  1.  Press  “SET”  button  to 

confirm, then the opener returns to standby mode. 

The default setting of safety reverse force is 5. 

Warning 

  Excessive  or  incorrect  force  settings  can 

cause damage or personal injury. We recommend only 

authorized Technicians should adjust force values and a 

safety reverse test should be carried out after manually 

adjusting this setting.   

Содержание 1000N

Страница 1: ...ore installation and use The installation of your new door opener should be carried out by a technically qualified person Attempting to install or repair the door opener without suitable technical qualification may result in severe personal injury death and or property damage TM ...

Страница 2: ...ck assembly optional 6 Battery backup assembly optional 7 Basic function settings 7 Special functions optional parts introduction and application 11 Manual disengagement 12 Maintenance 13 Final notes 13 Important information for the user 13 Packing list 14 Technical specifications 14 Common faults solutions 15 Warranty information 14 Warranty form 14 ...

Страница 3: ...thout observing all the applicable safety standards will be responsible for any damage injury expense or claim as a result of failure to install the system correctly and in accordance with the relevant safety standards For additional safety we recommend the inclusion of a Photo Beam System Although the opener incorporates a pressure sensitive Safety Obstruction Force system the addition of a Photo...

Страница 4: ...h a warning sign advising to keep children away from a moving garage door having a height of at least 60 mm Periodically check that this warning is still in place This garage door opener is supplied with an information card that should be attached to the manual release cord detailing the manual release procedure This garage door opener should be disconnected from its power source during cleaning a...

Страница 5: ...ing function so the garage door can still be locked manually in the event of a power outage 12 1200Nm lifting force 13 Safety reverse function The door will reverse to the fully open position when encountering a solid obstacle on closing cycle and stop when encountering excess resistance on the open cycle These values are adjustable from the menu 14 Backup battery interface available in case of po...

Страница 6: ...ances Important note It is thoroughly recommended that the installation of a garage door opener be carried out by a trained Technician DIY is an option but proceed at your own risk Installation 1 Read the instructions carefully 2 Make sure the door structure is solid and suitable to be motor driven 3 Make sure the door runs smoothly in manual operation before fitting an automatic opener 4 The door...

Страница 7: ...er falling and may cause serious damage and or personal injury Installation steel track 1 Fix the wall bracket B to the wall 2cm 15cm above the torsion shaft or spring and central to the door 2 Fix the steel track to the wall bracket using axis pin Φ8x80 C and cotter pin Fig 5 3 Fix garage door opener to the track using 2 x U brackets supplied E Then fasten using M6 nuts x4 supplied 4 Fix the hang...

Страница 8: ...r hexagon bolts and nuts supplied before connecting adjust to a suitable length 10 Release the clutch try to open and close the door by hand Make sure there is no contact between door panel and track 11 Connect the opener to power Notice Make sure the opener s voltage is in accordance with the local voltage Connect the opener to a properly earthed power supply Track Assembly Only required for segm...

Страница 9: ... illuminated Fig A Press a preferred button on transmitter once the LED dot will extinguish press the same button on the transmitter again The transmitter is now coded into the receiver Repeat the above steps to code more transmitters The receiver has the capacity to store 20 transmitters If the LED display flashes F and returns to standby mode after you have pressed the CODE button this indicates...

Страница 10: ...the position by momentarily pressing the UP and DOWN buttons to determine the final close limit position then press SET If the opener stops and displays H or C this indicates there s no hall signal or the opener is overloaded Call a Service Technician The opener will now operate a cycle automatically to remember the limit positions and the original opening closing force then return to standby mode...

Страница 11: ...y 1 minute The auto close function will be turned off when the LED displays 0 Press SET button to confirm the opener returns to standby mode The auto close function is only be available when the door is fully open and the photo beam function is on The default setting is o Press and hold SET button for 3 seconds until the LED flashes 1 Press UP button until the LED flashes 3 press SET button The di...

Страница 12: ...urns to standby mode When the lock door function is on and the door is fully closed the opener will lock the door automatically The door can only be opened by a transmitter after unlocking by the lock key S2 on the transmitter If not unlocked by the S2 button on the transmitter the light will flash twice when pressing the open key on the transmitter Press and hold SET button for 3 seconds until th...

Страница 13: ...s for this function and provide 24v 35v flashing light voltage Connect the flashing light with DC 24v 28v current 100mA When using AC 220V power flashing lights please match an adapter and wiring as required Fig 13 Pass door SD protection optional This function ensures that the door can t be opened unless a small pass door is closed Connect according to Fig 14 Fig 11 Fig 12 ...

Страница 14: ...ith the manual release cord To re engage the shuttle simply flick the manual release cord backwards so that the attaching arm is facing towards the opener head unit then run opener in automatic mode or move door by hand until the trolley engages in the chain shuttle spring loaded In some situations where no other access to the garage is possible it is recommended that an external disengagement dev...

Страница 15: ...nly to be used by technical persons who are qualified to carry out the installation It is important for the installer to show their clients correct operation of the opener including the procedure for manual disengagement Inform the owner about the need of regular maintenance especially regarding a regular check of the safety and reversing devices and systems Important information for the user Once...

Страница 16: ...sqm 18 0 sqm Rated lifting force 60 kgs 80 kgs 100 kgs 120 kgs Rail Steel Aluminum Steel Aluminum Steel Aluminum Steel Aluminum Drive Chain Belt Chain Belt Chain Belt Chain Belt Motor 24V 100W 24V 120W 24V 140W 24V 160W Input voltage 110V 270V 110V 270V 110V 270V 110V 270V LED 24V 14pcs LED bulbs Transformer 105 Temperature detect switch Radio frequency 433 92 MHz Coding format Rolling code 7 38x1...

Страница 17: ...y Safety reverse function Obstruction or door maintenance required 1 Check for any obstructions 2 Call a Professional Technician for maintenance Transmitter doesn t work 1 Flat battery 2 Antenna is loose or not well extended 3 Signal interference 1 Replace battery 2 Extend the antenna on the opener 3 Eliminate signal interference doorbell baby monitor alarm etc Can t add new transmitters 1 Memory ...

Страница 18: ...rees that they may be charged a call out fee plus any parts required to complete the repair Liability Australia only Under no circumstances shall the Seller be liable for consequential incidental or special damages arising in connection with the use or inability to use the Unit In no event shall the Seller s liability for damages or injury arising from breach of law or contract or for negligence e...

Страница 19: ...______ _______ Contact Details ______________________________________________________________________________________________ Notes_________________________________________________________________________________________ ________________________________________________________________________________________________________ 2019 Jaytech ...