Specifications
Ambiguity initialize
OTF (L1, L1/L2)
Baseline Length
Up to 50km in the morning and evening. Up to 32
km at noon.
Initialize time
5 seconds to 10 min depending on the base line
length and multipath conditions
Output interval for CMR/
RTCM
1Hz standard; 5, 10, 20Hz optional
Elevation
0 to 90 degrees (independent of data logging)
Solution mode
Delay (synchronization)
Extrapolation (not synchronized)
Process interval
1Hz standard; 5, 10, 20Hz optional
Latency
Delay mode - 20 msec to 20 sec (depends on latency
which receives corrections data from base receiver)
Extrapolation - 20 to 30 msec
Raw Data Logging
The receiver can record raw data at another interval
during RTK operation
Status
Fix, Float, DOP, Data Link Status, Modem Latency,
Common satellites, Percentage of fixing
Results
RTK coordinates, HRMS, VRMS, Covariance
Matrix
Ambiguity fixing level
Selectable thresholds Low: 95%; Medium: 99.5%;
High: 99.9%
PPS Output (optional)
Number of PPS ports
1
Edge
Rise, Fall
Period
10 to 1000000000 ms
Offset
-500000000 to 500000000 msec
-500000 to 500000 nsec
Reference time
GPS, GLONASS, UTC (USNO), UTC (SU)
Table B-1. Receiver Specifications (Continued)
Component
Details
Содержание Maxor
Страница 1: ...Maxor GNSS Receiver User s Manual Copyright Javad Navigation Systems Inc March 2004...
Страница 2: ......
Страница 8: ...VI Maxor User s Manual www javad com Notes...
Страница 12: ...X Maxor User s Manual www javad com LIST OF FIGURES RS 232C Connector B 10 USB Connector B 11...
Страница 20: ...XVIII Maxor User s Manual www javad com Notes...
Страница 70: ...2 36 Maxor User s Manual www javad com Notes...
Страница 138: ...E 2 Maxor User s Manual www javad com Notes...
Страница 142: ...Index Maxor User s Manual www javad com Notes...