FJ200 -CT USER`S MANUAL
V3.0
Page 18
Heating procedure
Before heating procedure device must be properly connected.
•
Place the device on the firm, plain and stable floor. It is recommended that the source
of cooling water and the drain is not more than 2 m away from the device.
•
Connect water supply to inlet hose and start filling procedure explained in chapter 3
•
Connect power supply to electric case.
•
Pour desired amount of milk into the kettle.
•
Turn on the device – Turn the main switch on (located on the side of the electric case).
•
Heating can begin when device is properly setup (see chapter 6).
•
Press green button to start the heating process. The red light on the upper left part of
control box is lit, indicating the heating is in progress. The display shows the present
temperature and begins to heat till setpoint temperature is reached.
•
After set temperature is reached heating transforms to holding, control unit beeps and
the holding time is displayed on screen.
•
Device switches to next phase automatically when holding time is passed and stops the
process automatically when fourth phase holding time is passed.
•
You can switch the phases if you want, by pressing the start key.
Cooling procedure
Before cooling procedure device must be properly connected. (see chapter 1, 3 and 5).
•
Connect cooling water to cooling water inlet connection
•
Connect drain hose to cooling water outlet connection.
Slowly open the valve on your water network or cooling tank, that you connected inlet hose to.
Cooling water supply must allways be connected to the device, device will open the flow
automatically, when needed. When setpoint temperature of milk will be lower than current
temperature of milk, the device will automatically start the cooling procedure. The blue light
on the upper left part of control box is lit, indicating the cooling is in progress. Cold water will
slowly come in the device’s plate exchanger and out through outlet hose to the drain or back
to cooling tank (differs from your connection). Cooling speed depends on cooling water
temperature and flow. When desired temperature is reached, cold water flow will be
automatically stopped by solenoid valve.
Cover the kettle with two part lid. If kettle is not covered with lid, the time of heating
will be longer and it will not reach maximal stated temperature!
ATTENTION:
Cooling water coming out of plate heat exchanger hose is hot!
Be careful that hose for outlet cooling water is free (is not pressed)
If you want to move on second process, even if first process is not finished yet, just
press key start.