To change mode for circulation pump, press
left key
to enter the settings menu.
Go to line “Circulat. Pump:” and then change
the value to “AUTO” by pressing down key.
•
With kettle properly vented you will have 1,5 bar pressure inside the kettle. During
operation you will have to check the water pressure regulary and add water if pressure
drops.
Water quality
The quality of the water used for washing, rinsing, heating, cooling is very important. The
water used must be appropriate for drinking. This requirements must be fulfiled to prevent
accumulation of bacteria on equipment surfaces. It is also important to prevent accumulation of
lime scale and to prevent corrosion on surfaces inside the device. Water must be clean both
microbiologically and chemically.
Microbiological requirements for water
All coliform bacteria
Absent in 100ml
Faecal coliform bacteria
Absent in 100ml
Faecal streptococci
Absent in 100ml
Spores of sulfide reducing clostridium
Absent in 100ml
Microflora standard (PCA) at 22°C
Less than 100 CFU in 1ml
Microflora standard (PCA) at 37°C
Less than 100 CFU in 1ml
Pathogenic microorganisms
Absent
Iron oxidizing bacteria
Absent
In the case of chlorination of non-potable water residues that could affect the quality of the
product or corrosion on the installations are not allowed.
Circulating pump
Manometer