FJ200 -CT USER`S MANUAL
V3.0
Page 10
Filling procedure:
•
Connect the tap water connection to inlet hose
•
Open the venting devices to let the air out
•
Choose to fill water at microcontroller and wait 2 minutes.
When electronics is energized it first checks
if heating water is present.
It offers to fill the water by pressing up key
or skip the choice by pressing down key.
Menu with water filling choice will
disappear in 5 seconds after start.
If no pressure is present it will not allow to
proceed.
When you choose to fill water, manually
connect the water supply to the device. You
must wait 2 minutes for the mixing valve to
change position before filling.
Slowly open the manual valve to
slowly fill
the water into the device.
After correct
pressure is formed
1,5 bar
, close the manual
valve and remove the water supply from the
device.
Manually start the pump by electronics by
pressing left key
to enter the settings
menu and to go to line “Circulat. Pump:”.
With
key change the value from
“AUTO” to “ON” .
•
Pump must circulate the water for so long that venting devices put all the air out of
system. Pressure may fall during this procedure, so more water must be added by
opening the valve at inlet hose to maintain the optimal pressure
1,5 bar
.
•
When kettle is vented, close the valve at inlet hose and remove the water connection
and stop the circulating pump.