FJ200 -CT USER`S MANUAL
V3.0
Page 15
Second page of settings menu offers:
-
Reduction of heating power
from
10-100 % with increments by 10 %
To decrease, press
key, to
increase, press
key.
-
Reduction of cooling power
from
10-100 % with increments by 10 %
To decrease, press
key, to
increase, press
key.
-
Option
for autostart the process
with entered setpoint table. To
autostart select “Y” with
key.
Clock can be set in this page of settings,
values can be changed by pressing up key
for increment and down key for decrease.
Third page of settings menu offers power
settings.
Power source
can be set:
-
Electric
(only electric heaters are
used for heating)
-
Ex electric
(External water
source is used to heat up milk to a
set temperature, above that
temperature external water source is
closed and only electro heaters are
used for heating)
-
External
(Only external water
source is used to heat up milk)
Switch temperature
of milk at which
switch between external power source and
electrical power source is made. (when
Eelectric is used)
Circulation pump
can be manually
switched on with pressing
key.