Model DP Oil-Fired Heater
Page 9
Avoid locating the chimney termination in a
location susceptible to downdraft conditions, or near
ventilation inlets to the building.
When venting multiple appliances through one
common duct, each appliance must have it's own
barometric draft control (see Figure 6). Refer to ANSI
Z223.1 or, in Canada, to CAN/CGA B149.1 or 2 for
more information on multiple venting.
SECTION 4.
Fuel Connections
4.1 Fuel Supply and Piping
Review the following general instructions before
continuing the installation.
WARNING
The Laars XL-3 pool and spa heater was designed for
use only with #2 fuel oil or #2 diesel.
DO NOT
ATTEMPT TO CONVERT THIS HEATER FOR USE
WITH ANY OTHER TYPE OF FUEL.
1.
Fuel piping installation must be in accordance
with all local or national codes that apply. Local
ordinances take priority over national codes.
Figure 6. Venting, Indoor Installation.
2.
Check the fuel supply to be sure that only #2 fuel
oil or #2 diesel fuel will be used to supply the
heater. Laars XL-3 heaters, as shipped from the
factory, are certified to operate at sea level but
the burner air shutter can be adjusted to operate
the heater efficiently at high altitudes
3.
Use the figures in Table 3 to size the fuel inlet
piping from the fuel storage tank to the heater.
Check all local codes for compliance before
installing the heater.
4.
Always install the fuel filter provided with the
heater in the fuel inlet pipe just outside the heater
jacket.
5.
Install an approved shutoff valve at the fuel
storage tank for service and safety.
6.
Before operating the heater, test the complete
gas supply system and all connections for leaks.
All XL-3 heaters are equipped with two-stage
fuel units. This enables the heater to be connected
with a either a single pipe or a two pipe fuel supply
system. In locations where the fuel storage tank is
above the level of the heater inlet, a single pipe system
may be used. Water Pik Technologies recommends a
two-pipe system, with a supply line and a return line
between the heater and the tank (see Figure 7), for all
Содержание DP3000