Page 4
POOL PRODUCTS
SECTION 2.
Installation Instructions
2.1 Introduction
WARNING
Improper installation or maintenance can cause
nausea or asphyxiation from carbon monoxide in flue
gases which could result in severe injury, or death.
CAUTION
The Laars XL-3 heaters are designed to operate at all
altitudes. Adjustments to the air band and end
shutter of the burner can be made to compensate for
changes in altitude. Contact your Jandy
representative or Water Pik Technologies' Customer
Service Department for more information.
Install the Laars XL-3 heater and vent systems in
accordance with the procedures in this manual, local
codes and ordinances, and in accordance with the
latest edition of the appropriate national code (see
Section 1.5 "Codes and Standards").
All oil-fired products require correct installation
to assure safe operation. The requirements for pool
heaters include the following:
1.
Field assembly (if required)
2.
Appropriate site location (clearances) and
flooring
3.
Sufficient combustion and ventilation air
4.
Properly sized fuel line.
5.
Proper electrical wiring
6.
Adequate water flow
This manual provides the information needed to
meet these requirements. Review all application and
installation procedures completely before continuing
the installation.
2.2. Field Assembly
The Laars XL-3 heater can be installed in a
variety of ways, some of them requiring preparation or
assembly in the field. The XL-3 is shipped with the
inner stack packaged on top of the control panel door
in the box with the heater. The inner stack must be
assembled and installed before mounting the vent cap
or vent pipe. To assemble the inner stack, remove the
tape and small envelope from the sheet metal coil.
Expand the coil until the holes on each end are aligned.
Use the two screws supplied in the small envelope to
secure the ends together. Install the inner stack, 7"
(18cm) diameter, on the collar of the flue collector
before attaching the vent cap (outdoor installation) as
shown in Figure 2. The Laars XL-3 heater is also
designed for "Indoor" installations in the United States
and "Outdoor Shelter" installations in Canada when
equipped with a barometric draft control and the
appropriately sized exhaust vent.
Check the Parts List (Section 10.2) of this
manual for the correct Jandy vent cap part number.
For specific installation information see Section 2.3.5
"Indoor and Outdoor Shelter Installations".
Water connections are provided on the right side
of the heater but can be changed to the left side by
reversal of the heat exchanger. It is best to handle
these preparations before the heater is installed in its
final location. See Section 5.4 "Reversible Water
Connections" of this manual for instructions.
2.3 Location Requirements
2.3.1 Introduction
CAUTION
When pool equipment is located below the pool
surface, a leak from any component can cause large
scale water loss or flooding. Water Pik Technologies
cannot be responsible for such water loss or flooding
or resulting damage.
The Laars XL-3 heater may be installed indoors
or outdoors as outlined in later sections. Location of
the heater below
or above
the pool deck affects
operation of its water pressure switch. See Section
5.1 water piping for more information about this.
Avoid placing the heater in locations where it can
cause damage by water or condensate leakage. If this
is not possible, provide a suitable drain pan to catch
and divert any leakage. The pan must not restrict the
air flow around the heater.
All criteria given in the following sections reflect
minimum clearances as stated in the national
standards. However, each installation must also be
evaluated, taking into account the prevailing local
Figure 2. Inner Stack.