Figure 10.  Wiring Power Pack to an AquaLink RS 

or PDA Power Center (240 VAC and 120 

VAC)

AquaLink RS or PDA Power Center

Filter Pump Relay

Aux. 3 Relay

Load

1

Line

1

120 VAC

To Filter Pump 

(120 VAC)

To Power Pack

(120 VAC)

Neutral

To Breaker 

Panel

Filter Pump Relay

Aux. 3 Relay

Load

2

Line

2

Load

1

Line

1

240 VAC

To Filter Pump 

(240 VAC)

To Power Pack

(240 VAC)

To Breaker 

Panel

Jandy

Power Center

Power Pack

OPTIONAL

4 3 2 1

RED

BLK

YEL

GRN

Red, 4-Pin

Terminal Bar

RED

GRN

YEL
BLK

B

A

0V

POS

RED

BLK

Figure 11.  Communication Wiring between Power 

Pack and AquaLink

®

 RS Control System 

or PDA Network

Cable Tie

Comm Hole

Figure 9. 

Accessing and Wiring to the Power PCB

7.  In the AquaLink

 

RS or PDA power center, wire the 

power pack directly 

to the LOAD SIDE of the filter 

pump relay (see Figure 10 and 12). 

8.  The AquaLink

 

RS or PDA and power pack 

 

use a 

four (4) wire connection to communicate and can be 

wired up to 500 feet apart. Any outdoor rated four 

conductor cable, minimum 22 AWG, can be used. 

Locate the appropriate screw terminals on the circuit 

board and wire the power pack

  

to the AquaLink

  

RS 

or PDA red 4-pin terminal bar  

(see Figure 11).

NOTE

  The screw terminals on the AquaLink RS or 

PDA are removable to aid in installation.

Page 6

 

Jandy

®

 Pro Series AquaPure

®

 Ei™ Series     

|

   Replacement Kit Instructions

Содержание AquaPure Ei Series

Страница 1: ...tion To order or purchase parts for the Jandy AquaPure Ei chlorine generating device contact your nearest Jandy dealer or distributor If they cannot supply you with what you need call Zodiac Pool Syst...

Страница 2: ...s and lifting up see Figure 2 Figure 1 Power Pack R Kits Outpu t Flow On O ff Salt Power Pack Cover Assembly R0512400 Power PCB Assembly R512100 Control PCB Assembly R512300 Output Cable Assembly R512...

Страница 3: ...able Assembly 1 Ensure that all power to the power pack and the controller is disconnected turned off at the circuit breaker 2 Remove the terminal cap from the cell and disconnect the cell leads 3 Det...

Страница 4: ...safety and safety of equipment B Bonding 1 The National Electrical Code NEC requires pool equipment to be bonded to each other Check your local codes to determine if the NEC and or other local install...

Страница 5: ...TVSS PCB Assembly to Green 4 pin connector see Figure 8 a Into Green 4 pin connector insert the Blue Wire into Pin 2 120v Or Neutral b Into Green 4 pin connector insert the Brown Wire into Pin 4 120v...

Страница 6: ...and AquaLink RS Control System or PDA Network Cable Tie Comm Hole Figure 9 Accessing and Wiring to the Power PCB 7 In the AquaLinkRS or PDA power center wire the power pack directly to the LOAD SIDE o...

Страница 7: ...power off to both devices and repeat steps 1 and 2 If the power pack still does not connect to the controller re check the wiring connections see Figure 10 and the controller setting on the power pac...

Страница 8: ...K RS OR PDA BLK YEL RED GRN RED BLK BLK NOT USED LOAD 2 LOAD 1 GROUND CHASSIS WHT TO EARTH BONDING POINT NOT USED NOT USED NOT USED TRI Ei TVSS PCBA BLUE BRN Figure 12 240 VAC or 120 VAC Wiring Diagra...

Отзывы: