  CAUTION

A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The 

conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures 

containing other conductors unless the additional conductors are also protected by a ground-fault circuit-

interrupter. Refer to local codes for complete details.

  CAUTION

A terminal bar marked "GROUND" is provided within the power center. To reduce the risk of electrical shock, 

connect this terminal bar to the grounding terminal of your electric service or supply panel with a continuous 

copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying this 

equipment, but no smaller than no. 12 AWG (3.3mm). In addition, a second wire connector should be bonded with 

a no. 8 AWG (4.115mm) copper wire to any metal ladders, water pipes, or other metal within five (5) feet (1.52m) 

of the tub.

  CAUTION

Control system is intended to control heaters with built-in high limit circuits only.

SAVE THESE INSTRUCTIONS

  WARNING

People with infectious diseases should not use a spa or hot tub.
To avoid injury, exercise care when entering or exiting the spa or hot tub.
Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible 

drowning.
Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub. 
Water temperature in excess of 100°F/38°C may be injurious to your health. 
Before entering a spa or hot tub measure the water temperature with an accurate thermometer. 
Do not use a spa or hot tub immediately following strenuous exercise.
Prolonged immersion in a spa or hot tub may be injurious to your health.
Do not permit any electric appliance (such as a light, telephone, radio, or television) within 5 feet (1.5 m) of a spa 

or hot tub.
The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
Water temperature in excess of 100°F/38°C may be hazardous to your health. 

  AVERTISSEMENT

Les personnes atteintes de maladies infectieuses ne devraient pas utiliser une cuve de relaxation.
Pour éviter des blessures, user de prudence en entrant dans une cuve de relaxation et en sortant.
Pour éviter l’évanouissement et la noyade éventuelle, ne prendre ni drougue ni alcool avant d’utiliser une cuve de 

relaxation ni quand on s’y trouve.

Les femmes enceintes, que leur grossesse soit confirmée ou non, devraient consulter un médecin avant d’utiliser 

une cuve de relaxation.
Il peut être dangereux pour la santé de se plonger dans de l’eau à plus de 38°C/100°F.
Avant d’utiliser une cuve de relaxation mesurer la témperature de l’eau à l’aide d’un thermomètre précis.
Ne pas utiliser une cuve de relaxation immédiatement après un exercice fatigant.
L’utilisation prolongée d’une cuve de relaxation peut être dangereuse pur la santé.
Ne pas placer d'appareil électrique (luminaire, téléphone, radio, téléviseur, etc) à moins de 1.5m de cette cuve de 

relaxation.
La consommation d’alcool ou de drogue augmente considérablement les risques d’hyperthermie mortelle dans 

une cuve de relaxation.
Il peut etrê dangereux pour la santé de se plonger dans de l’eau à plus de 38°C/100°F.

Attention installer:  

Install to provide drainage of compartment for electrical components.

Содержание AquaLink RS6

Страница 1: ...product must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may resul...

Страница 2: ......

Страница 3: ...nnecting Equipment to PCB 10 3 6 Setting DIP Switches 10 3 7 Installing Power Center Faceplate 10 Section 4 Power Center PCB DIP Switch Settings 11 4 1 DIP Switch Functions 11 4 2 DIP Switch Settings...

Страница 4: ...regnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Страница 5: ...ure the water temperature with an accurate thermometer Do not use a spa or hot tub immediately following strenuous exercise Prolonged immersion in a spa or hot tub may be injurious to your health Do n...

Страница 6: ...ional Relays when necessary OneTouch Control Panel Power Center PCB Three 3 Temp Sensors Additional Relays when necessary Standard Power Center with mounting brackets 4 3 HP Relays and RS Transformer...

Страница 7: ...age Class 2 1 A 24 VAC Emergency Service Switch All Circuits located at Power Center in Service Mode Dimensions 8 All Button Control Panel One TouchTM Control Panel Wireless Control Panel 14 1 2 3 4 5...

Страница 8: ...ol Intake Spa Intake Spa Return Pool Return Pool Filter Spa Filter Check Valve optional Check Valve Optional NOTE When connecting to the AquaLink RS plug the JVAs into the Intake Return and Cleaner JV...

Страница 9: ...rground or in concrete it must be run in conduit Never run high voltage and low voltage cables in the same conduit 2 Pull the Control Panel Cable into the low voltage compartment 3 Strip back cable ja...

Страница 10: ...uipment to PCB Connect the high voltage relay plugs into their appropriate sockets according to the wiring diagram located on the inside of the Power Center door see Section 5 Figure 5 NOTE Pool filte...

Страница 11: ...Valve Actuator does not rotate the spa will fill with water and overflow into the pool Note Leave AUX 3 relay socket empty CAUTION Turn this DIP Switch ON only if you are using an electric heater or a...

Страница 12: ...olar sensor Air temperature no longer displayed Adjustable Freese Kit must be added for freeze protection 8 After thermostat setting has been reached heater will remain OFF for 3 minutes Heat Pump ins...

Страница 13: ...ystem 2 NOT USED 3 NOT USED 4 NOT USED 4 4 DIP Switch Settings for Heat Pump Installation This table shows how to configure the system for SOLAR PRIORITY or HEAT PUMP PRIORITY DIP S2 1 GREEN 10 PIN TE...

Страница 14: ...o Sensors etc green terminal bar To Remote brown terminal bar To Controller red terminal bar F P u m p A u x 1 A u x 2 A u x 3 Relay Sockets 24 VDC output A u x 4 A u x 5 A u x 6 S p a P u m p C l e a...

Страница 15: ...Page 15 NOTES...

Страница 16: ...ns causing inadequate water circulation 6 Operating the product s at water flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in c...