Section 2.  System Overview

2.1  Package Contents

Package contents will depend on which AquaLink 

RS System you are installing. All Jandy AquaLink 

RS Systems come complete with the appropriate 

number of 3HP relays needed.

Control System Sub-Assemblies

All Button Dual Equipment

OneTouch Dual Equipment

Power Centers

All Button Control Panel, Power Center PCB,

Three (3) Temp Sensors, 

Additional Relays when necessary

OneTouch Control Panel, Power Center PCB,

Three (3) Temp Sensors,

Additional Relays when necessary

Standard Power Center

(with mounting brackets),

4-3 HP Relays, and RS Transformer

Sub-Panel Power Center (with mounting brackets), 

4-3 HP Relays, RS Transformer, Breaker Mount Plate, 

and GFCI Knockout

PureLink Sub-Panel Power Center (with mounting 

brackets) 4-3 HP Relays, RS Transformer,

Breaker Mount Plate, GFCI Knockout, AquaPure 

Transformer, and AquaPure PCB's

PureLink Power Center (with mounting brackets),

4-3 HP Relays, RS Transformer, 

AquaPure Transformer, and AquaPure PCB's

Содержание AquaLink RS6

Страница 1: ...product must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may resul...

Страница 2: ......

Страница 3: ...nnecting Equipment to PCB 10 3 6 Setting DIP Switches 10 3 7 Installing Power Center Faceplate 10 Section 4 Power Center PCB DIP Switch Settings 11 4 1 DIP Switch Functions 11 4 2 DIP Switch Settings...

Страница 4: ...regnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Страница 5: ...ure the water temperature with an accurate thermometer Do not use a spa or hot tub immediately following strenuous exercise Prolonged immersion in a spa or hot tub may be injurious to your health Do n...

Страница 6: ...ional Relays when necessary OneTouch Control Panel Power Center PCB Three 3 Temp Sensors Additional Relays when necessary Standard Power Center with mounting brackets 4 3 HP Relays and RS Transformer...

Страница 7: ...age Class 2 1 A 24 VAC Emergency Service Switch All Circuits located at Power Center in Service Mode Dimensions 8 All Button Control Panel One TouchTM Control Panel Wireless Control Panel 14 1 2 3 4 5...

Страница 8: ...ol Intake Spa Intake Spa Return Pool Return Pool Filter Spa Filter Check Valve optional Check Valve Optional NOTE When connecting to the AquaLink RS plug the JVAs into the Intake Return and Cleaner JV...

Страница 9: ...rground or in concrete it must be run in conduit Never run high voltage and low voltage cables in the same conduit 2 Pull the Control Panel Cable into the low voltage compartment 3 Strip back cable ja...

Страница 10: ...uipment to PCB Connect the high voltage relay plugs into their appropriate sockets according to the wiring diagram located on the inside of the Power Center door see Section 5 Figure 5 NOTE Pool filte...

Страница 11: ...Valve Actuator does not rotate the spa will fill with water and overflow into the pool Note Leave AUX 3 relay socket empty CAUTION Turn this DIP Switch ON only if you are using an electric heater or a...

Страница 12: ...olar sensor Air temperature no longer displayed Adjustable Freese Kit must be added for freeze protection 8 After thermostat setting has been reached heater will remain OFF for 3 minutes Heat Pump ins...

Страница 13: ...ystem 2 NOT USED 3 NOT USED 4 NOT USED 4 4 DIP Switch Settings for Heat Pump Installation This table shows how to configure the system for SOLAR PRIORITY or HEAT PUMP PRIORITY DIP S2 1 GREEN 10 PIN TE...

Страница 14: ...o Sensors etc green terminal bar To Remote brown terminal bar To Controller red terminal bar F P u m p A u x 1 A u x 2 A u x 3 Relay Sockets 24 VDC output A u x 4 A u x 5 A u x 6 S p a P u m p C l e a...

Страница 15: ...Page 15 NOTES...

Страница 16: ...ns causing inadequate water circulation 6 Operating the product s at water flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in c...

Отзывы: