background image

Sheet #6840, Rev

. J

Zodiac Pool Systems, Inc.

6000 Condor Drive, Moorpark, CA, USA 93021  •  800.822.7933  •  FAX 877.327.1403

Litho in U.S.A. © 2009 Zodiac Pool Systems, Inc. 0906

 

   

 

 

 

 

 

 

 

 

   

   

This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that 

have been moved from their original installation sites. The liability of Zodiac Pool Systems, Inc. shall not 

exceed the repair or replacement of defective parts and does not include any costs for labor to remove 

and reinstall the defective part, transportation to or from the factory, or any other materials required to make 

the repair. Refrigerant or other expendables are not covered by the warranty. This warranty does not cover 

failures or malfunctions resulting from the following:

LIMITED WARRANTY

• AquaLink

®  

RS units installed with Jandy

®

 Surge Protection Kits will be covered for two (2) years.

• Never Lube

®  

valves are warranted for the life of the pool and/or spa on which they were originally installed.

• AquaPure

®  

Electronic Chlorine Generator Electrolytic Cells carry a five (5) year limited warranty on a prorated basis.

• Heat pumps are covered for two (2) years. There is a lifetime warranty on titanium tubing.

• The heat pump compressor is covered for five (5) years.

• The DuoClear

®

 Electrolytic Cells carry a three (3) year limited warranty on a prorated basis.

• The DuoClear

®

 Vessels carry a three (3) year limited warranty.

1. Failure to properly install, operate, or maintain the product(s) in accordance with our published Installation,

    Operation, and Maintenance Manuals, which are provided with the product(s).

2. The workmanship of any installer of the product(s).

3. Not maintaining a proper chemical balance in your pool and/or spa [pH levels between 7.2 and 7.8, with 

    ideal ranges being between 7.4 and 7.6, Total Alkalinity (TA) between 80 to 120 ppm, 

    Total Dissolved Solids (TDS) less than 2000, not including salt ppm].

4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence, or acts of God.

5. Scaling, freezing, or other conditions causing inadequate water circulation.

6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.

7. Use of non-factory authorized parts or accessories in conjunction with the product(s).

8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing

    sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.

9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-rings, 

    DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.  

LIMITATION OF LIABILITY:

This is the only warranty given by Zodiac Pool Systems, Inc. No one is authorized to make any other warranties 

on behalf of Zodiac Pool Systems, Inc. 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, 

EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF FITNESS 

FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ZODIAC POOL SYSTEMS, INC. EXPRESSLY 

DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT, OR 

PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

 This warranty 

gives you specific legal rights. You may also have other rights that vary by state or province. 

WARRANTY CLAIMS:

For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, 

model number, serial number, and date of installation. The installer will contact the factory to obtain instructions 

regarding the claim and to determine the location of the nearest designated service center. If the dealer is not 

available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical 

support department at 1.800.822.7933 in the United States or 1.888.647.4004 in Canada. All returned parts must 

have a Returned Material Authorization number to be evaluated under the terms of this warranty. 

Thank you for purchasing Jandy

®

 pool and spa products. Zodiac Pool Systems, Inc. warrants all parts to be 

free from manufacturing defects in materials and workmanship for a period of one (1) year from the date of 

retail purchase, with the following exceptions:

Содержание AquaLink RS6

Страница 1: ...product must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may resul...

Страница 2: ......

Страница 3: ...nnecting Equipment to PCB 10 3 6 Setting DIP Switches 10 3 7 Installing Power Center Faceplate 10 Section 4 Power Center PCB DIP Switch Settings 11 4 1 DIP Switch Functions 11 4 2 DIP Switch Settings...

Страница 4: ...regnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Страница 5: ...ure the water temperature with an accurate thermometer Do not use a spa or hot tub immediately following strenuous exercise Prolonged immersion in a spa or hot tub may be injurious to your health Do n...

Страница 6: ...ional Relays when necessary OneTouch Control Panel Power Center PCB Three 3 Temp Sensors Additional Relays when necessary Standard Power Center with mounting brackets 4 3 HP Relays and RS Transformer...

Страница 7: ...age Class 2 1 A 24 VAC Emergency Service Switch All Circuits located at Power Center in Service Mode Dimensions 8 All Button Control Panel One TouchTM Control Panel Wireless Control Panel 14 1 2 3 4 5...

Страница 8: ...ol Intake Spa Intake Spa Return Pool Return Pool Filter Spa Filter Check Valve optional Check Valve Optional NOTE When connecting to the AquaLink RS plug the JVAs into the Intake Return and Cleaner JV...

Страница 9: ...rground or in concrete it must be run in conduit Never run high voltage and low voltage cables in the same conduit 2 Pull the Control Panel Cable into the low voltage compartment 3 Strip back cable ja...

Страница 10: ...uipment to PCB Connect the high voltage relay plugs into their appropriate sockets according to the wiring diagram located on the inside of the Power Center door see Section 5 Figure 5 NOTE Pool filte...

Страница 11: ...Valve Actuator does not rotate the spa will fill with water and overflow into the pool Note Leave AUX 3 relay socket empty CAUTION Turn this DIP Switch ON only if you are using an electric heater or a...

Страница 12: ...olar sensor Air temperature no longer displayed Adjustable Freese Kit must be added for freeze protection 8 After thermostat setting has been reached heater will remain OFF for 3 minutes Heat Pump ins...

Страница 13: ...ystem 2 NOT USED 3 NOT USED 4 NOT USED 4 4 DIP Switch Settings for Heat Pump Installation This table shows how to configure the system for SOLAR PRIORITY or HEAT PUMP PRIORITY DIP S2 1 GREEN 10 PIN TE...

Страница 14: ...o Sensors etc green terminal bar To Remote brown terminal bar To Controller red terminal bar F P u m p A u x 1 A u x 2 A u x 3 Relay Sockets 24 VDC output A u x 4 A u x 5 A u x 6 S p a P u m p C l e a...

Страница 15: ...Page 15 NOTES...

Страница 16: ...ns causing inadequate water circulation 6 Operating the product s at water flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in c...

Отзывы: