23
On the Setup Sections page, select
“3-Wire”
for the Section Valve Type. See
“Flow Monitor Set Up” on page 28 for information on the number of sections
and section widths.
On the Setup Control Valve page, select
“PWM Close”
for the Control Valve Type.
Enter
“50”
for the Valve Response Rate and
“2”
for the Control Deadband.
On the Setup PWM page, enter
“122”
for the Coil Frequency,
“85”
for the High
Limit %,
“20”
for the Low Limit % and
“0”
for the PWM Startup %.
Enter the Flowmeter Calibration number, approximately 1,340, which is stamped
on the flowmeter on the applicator. Also check and make sure the units are the
same as stamped on the flowmeter, usually Gallon
“10 gal” (H)
.
See your Rate Controller 2000 Manual for More Details
John Deere Rate Controller 2000 PWM Setup