13
Flow monitors allow the operator to check for blockages at each
coulter with a floating ball inside the transparent inspection tube.
Each coulter is connected with a separate supply hose.
The down pressure relief valve provides adjustable hydraulic pressure to force the coulters on the wings into the ground and keep the
coulters at the correct depth. While allowing the wing to flex up and down as needed to follow the contour of the ground.
•
Turn clockwise to increase down pressure.
•
Turn counter clockwise to decrease down pressure.
IMPORTANT -
It is
VERY IMPORTANT NOT TO EXCEED 1,350 psi
of pressure on the down pressure gauge. Excessive pressure can
cause premature wear on wing pivots and gauge wheels.
Flow Monitors
Down Pressure Relief Valve and Gauge
•
Set the center section of coulters first. Spacers are included with the toolbar cylinders. Add or remove spacers until the center
section is positioned at the appropriate depth. Lower the unit until the lift cylinders bottom out on the stroke control spacers. Add or
remove stroke control spacers until the center toolbar section reaches desired application depth. For best results, move forward while
lowering the toolbar.
•
After the center toolbar is set with the cylinder spacers, adjust the wing gauge wheel setting until the wings are level with the base
section and the entire toolbar is flat and even. Once the toolbar is set and leveled, further adjustment is typically not necessary.
Adjusting the Field Depth
The NitroGro applicator is equipped with a strainer designed to remove dirt and debris from the
fertilizer to prevent downstream clogs.
Should be cleaned daily.
Strainer