20
Initial Console Programming
HINT: If you enter the wrong value when entering your data press “ENTER” then press “ENTER” again and re-enter your value again.
•
Select the unit of measurement by pressing the CE button until the desired selection appears in the display and press “ENTER”
NOTE - The unit of measurement for the United States is Volume per Acre.
•
Select the type of sensor by pressing the CE button until the desired sensor type appears in the display and press “ENTER”.
For Phoenix 10, select SP2.
For wheel drive sensor, select SP1.
•
The message “CAL C-SD STANDARD VALVE” will appear in the console’s display.
For PWM pump, press CE until C-P-C PWM appears. Press “ENTER”.
•
The message “CAL SELF TEST 00” will appear in the console’s display. Press the “BOOM CAL 1” button and enter the value shown in the
table below. To store the values, press “ENTER” (the enter button will light up), input the value and then press “ENTER” to store your
value. Repeat for Boom 2 through 5. Press the arrow keys to advance to the remaining booms.
•
Press the “SPEED CAL” button and input the appropriate speed calibration value for the type of sensor being used and press “ENTER”.
For Phoenix 10, the speed calibration is 785.
For wheel drive sensor, refer to the speed calibration steps in the Raven SCS 450 operator’s manual.
•
Press the “METER CAL” button and enter the meter calibration value stamped on the flow meter’s identification tag.
The meter calibration value is approximately 1,340 gallons. Check the stamped valve to be sure.
•
Press the “VALVE CAL” button and input the calibration number that corresponds with the control valve being used and press “ENTER”.
For PWM Pump, the valve calibration is 0043 or 43. If the pump does not react fast enough to the desired rate, 33 can be
entered here to speed up the controller’s reaction time.
•
Press the “RATE 1 CAL” button and “ENTER” the Rate 1 value. Refer to the “Calculate the Rate 1 and Rate 2 Cal Values” section of the
Raven SCS 450 manual and press “ENTER”.
•
Press the “RATE 2 CAL” button and “ENTER” the Rate 2 value. Refer to the “Calculate the Rate 1 and Rate 2 Cal Values” section of the
Raven SCS 450 manual and press “ENTER”.
•
The initial console programming is now complete, and the flashing “CAL” in the console’s display should turn off. If it does not, repeat
the procedure starting from the first step above.
•
These settings will be stored and the previous steps do not need to be repeated after powering off or on.
•
Adjust the PWM offsets by selecting “Data Menu” and use the arrows to find the high PWM and Lowe PWM offsets. Set the high PWM
offset to 220 and the low PWM offset to 50. Next, find the PWM frequency and set it to 122.
RESET: If an entry or selection error is made during any steps of this procedure, turn the POWER switch to the OFF position, press and
hold CE while turning the POWER switch to the ON position to reset the console.
Boom #
Value
Boom 1
135
Boom 2
150
Boom 3
150
Boom 4
150
Boom 5
135
Raven 450 Controller Set Up
Scan to watch
the video