2-1/2” Filter Cap Assembly
Remove the caps from each of the filter housings (VHPR135).
Following the PTFE Tape & Tightening Guidelines in
Section E
, tape and assemble two threaded adapters (PP10461) to each filter housing cap as shown below.
Set all three caps on a flat surface and arrange caps so IN and OUT are as shown below.
Following the PVC Gluing Guidelines in
Section E
, prime and glue a section of 4” tube between each cap as shown below.
IS275-17L
J&D Manufacturing • 6200 Hwy 12 • Eau Claire, WI 54701 • 1-800-998-2398 • www.jdmfg.com
Section F - Page 2/6
Section F
Filter System Assembly & Installation
Section F
IN
OUT
IN
OUT
IN
OUT
4”
Prime & Glue
Prime & Glue
Prime & Glue
Prime & Glue
4”
2-1/2” Filter Cap Assembly
PP10461
Adapter
PTFE
Tape
PTFE
Tape
PP10461
Adapter
Cap Only - VHPR135
2-1/2” Filter Housing
6
If your filter system uses 4-1/2” filter housings, proceed to Step 8.
Attaching Brackets to 2-1/2” Filter Cap Assembly
Using either a #3 phillips head hand driven screwdriver or a #3 phillips head drill bit and drill with its clutch/torque adjusted to not strip the holes, secure the three
filter mounting brackets (VHPR142) to the filter cap assembly using (4) #14–10 x 3/4” phillips pan head screws per bracket as shown below.
7