Input/output
–
Analog Out [1]&[2]
7. In/Output -
The flowmeter is available for 4-20m ADC output with two configurations. User can
assign each data with Analog Out [1] and [2] individually.
7.1 In/Output –
Analog Out [1]
The flowmeter has two analog output for 4-20m ADC. Both Analog Out [1] and
Analog Out [2] has exactly same functions to output data.
7.1.1 In/Output –
Analog Out [1] –
Output Data
User can assign Flow or Velocity to Analog Out.
7.1.2 In/Output –
Analog Out [1] –
Output Mode
In the case of Open Channel, User shall use the default setting, by application.
7.1.3 In/Output –
Analog Out [1] –
Calibration_Min
Caution) Do NOT use this function without manufacture’s technical instructions.
7.1.4 In/Output –
Analog Out [1] –
Calibration_Max
Caution) Do NOT use this function without manufacture’s technical instructions.
7.1.5 In/Output –
Analog Out [1] –
Span Min
User can use this menu to set the Span Minimum for the flow.
MAIN MENU
1 .
GENERAL
2 .
PATH SELECT
3 .
CH SETUP
4 .
INSTALL
5 .
OPERATE
6 .
FLOW
7 .
IN/OUTPUT
8 .
DATALOG
9 .
DIAG
IN/OUTPUT
1 . ANALOG OUT [1]
2 . ANALOG OUT [2]
3 . RELAY OUT [1]
4 . RELAY OUT [2]
5 . ANALOG IN [1]
6 . ANALOG IN [2]
ANALOG OUT [1]
1 . OUTPUT DATA
2 . OUTPUT MODE
3 . CALIBRATION_MIN
4 . CALIBRATION_MAX
5 . SPAN MIN
6 . SPAN MAX
7 . 2mA SET
OUTPUT DATA
1 . NONE
2 . FLOW
3 . VELOCITY
4 . ANALOG IN 1
5 . ANALOG IN 2
1 . OUTPUT DATA
2 . OUTPUT MODE
3 . CALIBRATION_MIN
4 . CALIBRATION_MAX
5 . SPAN MIN
6 . SPAN MAX
7 . 2mA SET
ANALOG OUT [1]
1 . BY APPLICATION
2 . [CH 1] ONLY
3 . [CH 2] ONLY
OUTPUT MODE
1 . OUTPUT DATA
2 . OUTPUT MODE
3 . CALIBRATION_MIN
4 . CALIBRATION_MAX
5 . SPAN MIN
6 . SPAN MAX
7 . 2mA SET
ANALOG OUT [1]
SPAN MIN
m³/h
0
Press [
MENU
] –
7. IN/OUTPUT
▪
Analog Output [1]&[2]
▪
Relay Out [1]&[2]
▪
Analog In [1]&[2]
Press [
MENU
] – 7. IN/OUTPUT –
1. ANALOG OUT
[1]
– 1. OUTPUT DATA
▪
None – Disable Output Function
▪
Output the Flow Data
▪
Output the Velocity Data
▪
Re-transmit the Data from Analog Input [1]
▪
Re-transmit the Data from Analog Input [2]
▪
Press [
MENU
] – 7. IN/OUTPUT –
1. ANALOG OUT
[1] –
2. OUTPUT MODE
▪
By Application – Set Up by the program.
▪
[CH 1] only – Not available for Open Channel
▪
[CH 2] only – Not available for Open Channel
Press [
MENU
] – 7. IN/OUTPUT –
1. ANALOG OUT [1] –
3. CALIBRATION_MIN
Press [
MENU
] – 7. IN/OUTPUT–1. ANALOG OUT [1] –
4. CALIBRATION_MAX
Press [
MENU
] – 7. IN/OUTPUT –
1. ANALOG OUT [1] –
5. SPAN MIN
➢
The value should be same with the minimum flow
user set in the menu, 5.2 Lower Flow Limit.
Содержание Xonic 100 Series
Страница 42: ...Xonic 100 Series Jain Technology www jain co kr Tel 82 2 856 4114 Fax 82 2 856 9503 42 DRAWINGS...
Страница 43: ...Xonic 100 Series Jain Technology www jain co kr Tel 82 2 856 4114 Fax 82 2 856 9503 43...
Страница 44: ...Xonic 100 Series Jain Technology www jain co kr Tel 82 2 856 4114 Fax 82 2 856 9503 44...
Страница 45: ...Xonic 100 Series Jain Technology www jain co kr Tel 82 2 856 4114 Fax 82 2 856 9503 45...
Страница 46: ...Xonic 100 Series Jain Technology www jain co kr Tel 82 2 856 4114 Fax 82 2 856 9503 46...
Страница 47: ...Xonic 100 Series Jain Technology www jain co kr Tel 82 2 856 4114 Fax 82 2 856 9503 47...