![JAI GOX-5105M-PGE Скачать руководство пользователя страница 75](http://html2.mh-extra.com/html/jai/gox-5105m-pge/gox-5105m-pge_user-manual_3228013075.webp)
User Manual (Ver. 1.0) - Main Functions
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 75 -
GOX-24505M-PGE, GOX-24505C-PGE
Exposure Mode = Timed (Frame Start Trigger On, RCT Mode)
Pixel Format
Frame Period [A] (usec)
Period From Trigger Start
Edge to Exposure Start [B]
(usec)
Data Invalid Period [C]
(usec)
Full (Max Frame Rate), Exposure Time Minimum
Mono8
203422
1919.8
-901
Mono10
Mono12
405616
1923.1
439
Mono10Packed
Mono12Packed
304550
1923.0
-231
BayerRG8
203422
1919.8
-901
BayerRG10
BayerRG12
405616
1923.1
439
BayerRG10Packed
BayerRG12Packed
304550
1923.0
-231
Binning Horizontal (Max Frame Rate), Exposure Time Minimum
Mono8
102520
1919.2
-1418
Mono10
Mono12
203585
1921.0
-730
Mono10Packed
Mono12Packed
153065
1922.8
-1103
Binning Vertical (Max Frame Rate), Exposure Time Minimum
Mono8
102511
1922.4
-1435
Mono10
Mono12
203585
1922.0
-759
Mono10Packed
Mono12Packed
153065
1922.8
-1120
Binning Horizontal & Binning Vertical (Max Frame Rate), Exposure Time Minimum
Mono8
102223
1923.0
20009
Mono10
Mono12
102601
1922.4
-1372
Mono10Packed
Mono12Packed
102223
1923.0
20009