User Manual (Ver. 1.0) - Main Functions
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 73 -
GOX-16205M-PGE, GOX-16205C-PGE
Exposure Mode = Timed (Frame Start Trigger On, RCT Mode)
Pixel Format
Frame Period [A] (usec)
Period From Trigger Start
Edge to Exposure Start [B]
(usec)
Data Invalid Period [C]
(usec)
Full (Max Frame Rate), Exposure Time Minimum
Mono8
135065
1909.2
-1786
Mono10
Mono12
269308
1909.8
3
Mono10Packed
Mono12Packed
201962
1909.6
-1133
BayerRG8
135065
1909.2
-1786
BayerRG10
BayerRG12
269308
1909.8
3
BayerRG10Packed
BayerRG12Packed
201962
1909.6
-1133
Binning Horizontal (Max Frame Rate), Exposure Time Minimum
Mono8
102336
1909.7
31683
Mono10
Mono12
135229
1909.2
-1657
Mono10Packed
Mono12Packed
102250
1909.6
-1558
Binning Vertical (Max Frame Rate), Exposure Time Minimum
Mono8
102336
1909.6
31677
Mono10
Mono12
135229
1909.6
-1685
Mono10Packed
Mono12Packed
102250
1909.6
-1541
Binning Horizontal & Binning Vertical (Max Frame Rate), Exposure Time Minimum
Mono8
102222
1909.6
45905
Mono10
Mono12
102222
1909.7
28382
Mono10Packed
Mono12Packed
102222
1909.6
45905