User Manual (Ver. 1.0) - Main Functions
GO-5000M-PMCL-1 | GO-5000M-PMCL-EP-1 | GO-5000M-PMCL-UV-1
- 49 -
1x8-1Y (1 Line Clock, Horizontal Frequency/Period)
Horizontal Timing (Continuous Trigger Mode) (2/2)
Note:
A: Operation Value; B = Calculation Value
Camera Settings
A: Operation value B: Calculation value
Tap
Geometry
Camera Link
Pixel Clock
ROI
Binning
1 line Total
clock (Unit:
clock)
Horizontal
Frequency (Unit:
kHz)
Horizontal
Period (Unit:
us)
Width
Offset
X
Height
Offset
Y
Horizontal Vertical
1X8 - 1Y
8bit
72.85 MHz
2560
0
2048
0
Off
Off
A
330
220.751
4.53
B
330
220.779
4.529
1280
0
2048
0
x2
Off
A
330
220.751
4.53
B
330
220.779
4.529
640
0
2048
0
x4
Off
A
330
220.751
4.53
B
330
220.779
4.529
2560
0
1024
0
Off
x2
A
330
220.751
4.53
B
330
220.779
4.529
1280
0
1024
0
x2
x2
A
330
220.751
4.53
B
330
220.779
4.529
640
0
1024
0
x4
x2
A
330
220.751
4.53
B
330
220.779
4.529
2560
0
512
0
Off
x4
A
330
220.751
4.53
B
330
220.779
4.529
1280
0
512
0
x2
x4
A
330
220.751
4.53
B
330
220.779
4.529
640
0
512
0
x4
x4
A
330
220.751
4.53
B
330
220.779
4.529