User Manual (Ver. 1.0) - Main Functions
GO-5000M-PMCL-1 | GO-5000M-PMCL-EP-1 | GO-5000M-PMCL-UV-1
- 55 -
Camera Settings
A: Operation value B: Calculation value
Tap
Geometry
Camera Link
Pixel Clock
ROI
Binning
1 line Total
clock (Unit:
clock)
Horizontal
Frequency (Unit:
kHz)
Horizontal
Period (Unit:
us)
Width
Offset
X
Height
Offset
Y
Horizontal Vertical
1X4 - 1Y
48.57 MHz
2560
0
2048
0
Off
Off
A
651.2
74.571
13.41
B
652
75.421
13.259
1280
0
2048
0
x2
Off
A
334.2
154.349
6.88
B
335
144.989
6.897
640
0
2048
0
x4
Off
A
329.3
147.493
6.78
B
330
147.186
6.794
2560
0
1024
0
Off
x2
A
651.2
74.571
13.41
B
652
75.42
13.259
1280
0
1024
0
x2
x2
A
334.2
154.349
6.88
B
335
144.989
6.897
640
0
1024
0
x4
x2
A
651.2
74.571
13.41
B
652
75.421
13.259
2560
0
512
0
Off
x4
A
334.2
154.349
6.88
B
335
144.989
6.897
1280
0
512
0
x2
x4
A
651.2
74.571
13.41
B
652
75.421
13.259
640
0
512
0
x4
x4
A
334.2
154.349
6.88
B
335
144.989
6.897