User Manual (Ver. 1.0) - Short ASCII Command List
GO-5000M-PMCL-1 | GO-5000M-PMCL-EP-1 | GO-5000M-PMCL-UV-1
- 100 -
Acquisition Control
Related Topic:
Name
Access
Short ASCII
Values
Default
Description
FrameStartTrig Mode
R/W
TM
0: Off
1: On
0
TM=[Param.]<CR><LF>
TM?<CR><LF>
TriggerSoftware
(R)/W
STRG
0, 1
-
STRG=0<CR><LF>
FrameStartTrig Source
R/W
TI
0: Low
1: High
2: SoftTrigger
8: PulseGenerator0
13: CL_CC1_In
14: Nand0
15: Nand1
0
TI=[Param.]<CR><LF>
TI?<CR><LF>
FrameStartTrig Activation
R/W
TA
0: RisingEdge
1: FallingEdge
2: LevelHigh
3: LevelLow
0
TA=[Param.]<CR><LF>
TA?<CR><LF>
ExposureMode
R/W
EM
0: Off
1: Timed
2: TriggerWidth
0
EM=[Param.]<CR><LF>
EM?<CR><LF>
ExposureTime
Raw
R/W
PE
10 ~ 8000000[us]
18000
PE=[Param.]<CR><LF>
PE?<CR><LF>
ExposureAuto
R/W
ASC
0: Off
1: Continuous
0
ASC=[Param.]<CR><LF>
ASC?<CR><LF>