User Manual (Ver. 1.0) - Short ASCII Command List
GO-5000M-PMCL-1 | GO-5000M-PMCL-EP-1 | GO-5000M-PMCL-UV-1
- 106 -
Name
Access
Short
ASCII
Values
Default
Description
SequenceROI
OffsetY(n)
(n) = 1 ~ 128
R/W
SQOY(n)
0 ~ 2047
0
SQOY(n)=[Param.]<CR><LF>
SQOY(n)?<CR><LF>
SequenceROI Gain
(n)
(n) = 1 ~ 128
R/W
SQGA(n)
100 ~1600
0
SQGA(n)=[Param.]<CR><LF>
SQGA(n)?<CR><LF>
SequenceROI
ExposureTime(n)
(n) = 1 ~ 128
R/W
SQPE(n)
10 ~ 8000000
18000
SQPE(n)=[Param.]<CR>
SQPE(n)?<CR><LF>
SequenceROI
Hbinning(n)
(n) = 1 ~ 128
R/W
SQHB(n)
1: Hbinning = OFF
2: Hbinning = x2
4: Hbinning = x4
1
SQHB(n)=[Param.]<CR><LF>
SQHB(n)?<CR><LF>
SequenceROI
Vbinning(n)
(n) = 1 ~ 128
R/W
SQVB(n)
1: Vbinning = OFF
2: Vbinning = x2
4: Vbinning = x4
1
SQVB(n)=[Param.]<CR><LF>
SQVB(n)?<CR><LF>
SequenceROI
LutEnable(n)
(n) = 1 ~ 128
R/W
SQLUT(n)
0: Off
1: On
0
SQLUT(n)=[Param.]<CR><LF>
SQLUT(n)?<CR><LF>
SequenceROI
BlackLevel(n)
(n) = 1 ~ 128
R/W
SQBL(n)
-256 ~ 255
0
SQBL(n)=[Param.]<CR><LF>
SQBL(n)?<CR><LF>
CommnadSequence
Index
R/W
CSQI
0 ~ 127
0
CSQI=[Param.]<CR><LF>
CSQI?<CR><LF>
CurrentSequence
Index
R/O
SQIDX
0 ~ 127
0
SQIDX?<CR><LF>
SequenceReset
W/O
SQRST
0
0
SQRST=[Param.]<CR><LF>
SequenceLutMode
R/W
SQLUT
0: Gamma
1: LUT
0
SQLUT=[Param.]<CR><LF>
SQLUT?<CR><LF>
MultiRoiIndexMax
Related Topic:
R/W
MRIM
1 ~ 5
1
MRIM=[Param.]<CR><LF>
MRIM?<CR><LF>
MultiRoiWidth
R/W
MRW
8 ~ 2560
2560
MRW=[Param.]<CR><LF>
MRW?<CR><LF>
MultiRoiHeight1
R/W
MRH1
0 ~ 2048
2048
MRH1=[Param.]<CR><LF>
MRH1?<CR><LF>