AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
Main Functions
- 60 -
Trigger Sequencer mode
With this mode, the Sequencer Trigger “pattern” is predetermined by the user. The user defines up to
128 different “indexes.” The items indicated in the above index can be configured for each index. The
operation of this mode is controlled using the following commands.
Note:
In Trigger Sequencer Mode, when set
SequencerMode
to
On
,
FrameStart
(TriggerMode)
is forced to be
On
. When
SequencerMode
is returned to
Off
,
FrrameStart
(TriggerMode) will
remain
On
.
Sample TriggerSequencer mode operation
User-defined Indexes (up to 128)
1. Specify "1" in
SequencerSetStart
, and start TriggerSequencer mode with index 1.
2. Capture a 2-frame image with the first and second triggers.
3. For the next index, configure index 3 specified in
SequencerSetNext
, and capture an image with the
number of frames (number of triggers) specified in
SequencerFrameNumber
. Proceed to sequence
from index 4 to index 2 to index 1.
Note:
In addition to repeating multiple conditions as in the example above, you can also specify 0
to indicate the end of TriggerSequencer mode in [SequencerSetNext] of index 2, and specify the
number of repetitions in [SequencerRepetition].