ALC Control Item
Setting Range
Default
Description
AutoGainControlGainRaw
Max
(AutoGainControlGain
1) ~ 800
400 or 800
Set the maximum value for the GainAuto(ASC)
control range. The default value depends on the
Gain setting.
ALCControlSpeed
1 (slow) ~ 8 (fast)
4
Set the response speed for AGC/ ASC. (8 is the
fastest.) (When ALCControlMode is set to
Standard.)
ALCStatus
Off
ASC
AGC
-
Allows confirmation of the current operation
area during ALC operation.
AutoControlStatus
Executing ASC
Executing AGC
Executing ASC and AGC
Executing AWB
Executing ASC and AWB
Executing AGC and AWB
Executing ASC and AGC and AWB
Convergent
Idle
-
Allows confirmation of the AGC, ASC, and AWB
convergence status.