AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
Main Functions
- 40 -
TriggerSelector
Description
AcquisitionTransferStart
Output acquired images at a specified timing in response to an external trigger
signal input.
Note
: There is a limit to the number of image frames that can be stored
internally. The limits for each image format are as follows.
8bit: Up to 16 frames
10bit /12bit: Up to 8 frames
Note:
The settings for exposure control and triggers are related to each other. Be sure to
configure the settings described in “
”.
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The shortest
repetition periods for triggers cannot be lower than that value.
Scanning Range
AP-1600T-USB
AP-3200T-USB
Height BGR8 (8bit) BGR10p (10bit) BGR12p (12bit) Height BGR8 (8bit) BGR10p (10bit) BGR12p (12bit)
Full
1088
12.7ms
15.9ms
19.0ms
1544
26.1ms
32.6ms
39.1ms
ROI (1/2)
544
6.3ms
7.9ms
9.5ms
772
13.3ms
16.6ms
20.0ms
ROI (1/4)
272
3.2ms
4.0ms
4.8ms
386
6.9ms
8.7ms
10.4ms
BinningVertical = 2
544
6.3ms
7.9ms
9.5ms
772
26.1ms
32.6ms
39.1ms
The above table indicates the shortest trigger periods for when
Trigger OverLap
is set to
Readout
.
When
Trigger OverLap
is set to
Off
, the exposure time is added to the period.